4OM-1075-002 - 第145页
Error ID Item Description 0c0102 Backup Up/Down Axis Origin Origin sensor (slide) was not detected. 0c0103 Backup Up/Down Axis Origin Origin sensor (slide) and Limit error has been de- tected. (Cause 1) The backup U/D ax…

Error ID Item Description
0b0601 Nozzle Change #2 Interlock Step out was detected.
0b0602 Nozzle Change #2 Interlock
0b0603 Nozzle Change #2 Interlock
0b0604 Nozzle Change #2 Interlock
0b0605 Nozzle Change #2 Interlock
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
0b0701 Nozzle Change #2 Operation Error Nozzle Change result error.
0b0702 Nozzle Change #2 Operation Error Nozzle Change result error.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
0c0101 Backup Up/Down Axis Origin Encoder origin was not detected.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
3.3 Error IDs and Remedial Procedures
0308-002 2-54 AHB01ETRP

Error ID Item Description
0c0102 Backup Up/Down Axis Origin Origin sensor (slide) was not detected.
0c0103 Backup Up/Down Axis Origin Origin sensor (slide) and Limit error has been de-
tected.
(Cause 1) The backup U/D axis might have overrun due to a defective sensor, a broken cable,
generation of noises, or overcurrent.
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
0c0104 Backup Up/Down Axis Origin Feedback value is indefinite.
0c0105 Backup Up/Down Axis Origin BPC axis is not at origin.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
3.3 Error IDs and Remedial Procedures
0308-001 2-54-1 AHB01ETRP

Error ID Item Description
0c0201 Backup Up/Down Axis Timing Task has not been completed unable to continue.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
0c0301 Backup Up/Down Axis Data The driver data was detected outside of the possible
range.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
0c0401 Backup Up/Down Axis Limit (+) Limit error has been detected.
0c0402 Backup Up/Down Axis Limit (-) Limit error has been detected.
(Cause 1) The X1 axis might have overrun due to generation of noises, overcurrent, etc.
The sensor may be defective.
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
0c0502 Backup Up/Down Axis Servo Alarm Parameter breakdown.
0c0503 Backup Up/Down Axis Servo Alarm Main circuit encoder error.
0c0504 Backup Up/Down Axis Servo Alarm Parameter setting error.
0c0505 Backup Up/Down Axis Servo Alarm Combination error.
0c0510 Backup Up/Down Axis Servo Alarm Overcurrent or heat sink overheated.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
3.3 Error IDs and Remedial Procedures
0107-001 2-55 AHB01ETRP