0206-002 2-69 AHB01ETRP 3.3 Error IDs and Remedial Procedures Error ID Item Description 1 12002 T V # 1 Axis Precheck 1 12003 T V # 1 Axis Precheck 1 12004 T V # 1 Axis Precheck 1 12005 T V # 1 Axis Precheck Pallet insta…

Error ID Item Description
111003 TV #1 Axis Precheck Safty relay off.; K504
111004 TV #1 Axis Precheck Safty relay off.; K502
111005 TV #1 Axis Precheck Pallet installation error detected.; BPH504/505
111006 TV #1 Axis Precheck Rack shutter opened.; BPS502/504
111007 TV #1 Axis Precheck Pallet chuck opened.; BPS512
111008 TV #1 Axis Precheck L1 Axis Zeroing not completed
111009 TV #1 Axis Precheck
11100a TV #1 Axis Precheck
11100b TV #1 Axis Precheck Pallet detected.; BPS514
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service per-
sonnel for the remedy.
11100c TV #1 Axis Precheck
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Remove the mispicked component on the tray.
11100d TV #1 Axis Precheck
11100e TV #1 Axis Precheck
11100f TV #1 Axis Precheck Incorrect No. of Drawing Step
112001 TV #1 Axis Precheck
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
3.3 Error IDs and Remedial Procedures
0206-003 2-68 AHB01ETRP

0206-002 2-69 AHB01ETRP
3.3 Error IDs and Remedial Procedures
Error ID Item Description
112002 TV #1 Axis Precheck
112003 TV #1 Axis Precheck
112004 TV #1 Axis Precheck
112005 TV #1 Axis Precheck Pallet installation error detected on operator side.;
BPH505
112006 TV #1 Axis Precheck Rack shutter closed.; BPS501/503
112007 TV #1 Axis Precheck
112008 TV #1 Axis Precheck
112009 TV #1 Axis Precheck
11200a TV #1 Axis Precheck
11200b TV #1 Axis Precheck
11200c TV #1 Axis Precheck Pallet found on returning step (BPH520, 521)
11200d TV #1 Axis Precheck
11200e TV #1 Axis Precheck
11200f TV #1 Axis Precheck
113001 TV #1 Axis Precheck
113002 TV #1 Axis Precheck
113003 TV #1 Axis Precheck
113004 TV #1 Axis Precheck
113005 TV #1 Axis Precheck Pallet installation error detected on traverse side;
BPH504
113006 TV #1 Axis Precheck
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.

Error ID Item Description
113007 TV #1 Axis Precheck
113008 TV #1 Axis Precheck
113009 TV #1 Axis Precheck
11300a TV #1 Axis Precheck
11300b TV #1 Axis Precheck
11300c TV #1 Axis Precheck
11300d TV #1 Axis Precheck
11300e TV #1 Axis Precheck
11300f TV #1 Axis Precheck
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
11f001 TV #1 Axis Operation Error Tray No. Error
11f002 TV #1 Axis Operation Error Step No. Error
11f003 TV #1 Axis Operation Error Designated speed error.
11f004 TV #1 Axis Operation Error Destination error
11f005 TV #1 Axis Operation Error Destination error
11f006 TV #1 Axis Operation Error Overtime in Operation
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
3.3 Error IDs and Remedial Procedures
0206-003 2-70 AHB01ETRP