4OM-1075-002 - 第164页

Error ID Item Description 120109 T V # 2 Axis Origin Pallet detected. (5402) 12010a T V # 2 Axis Origin Operation not completed normally . (5403) 12010b T V # 2 Axis Origin Zeroing not completed within specified time. (5…

100%1 / 299
Error ID Item Description
11f007 TV #1 Axis Operation Error A limit error or a component pickup error was de-
tected during movement.
11f008 TV #1 Axis Operation Error Emergency stop
11f009 TV #1 Axis Operation Error A component pickup error was detected during
movement.
11f00a TV #1 Axis Operation Error
11f00b TV #1 Axis Operation Error
11f00c TV #1 Axis Operation Error
11f00d TV #1 Axis Operation Error
11f00e TV #1 Axis Operation Error
11f00f TV #1 Axis Operation Error
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
120101 TV #2 Axis Origin Rack shutter not opened within specified time. (5101)
120102 TV #2 Axis Origin Pallet chuck not closed within specified time. (5102)
120103 TV #2 Axis Origin Operatiing condition for zeroing not fulfilled. (5103)
120104 TV #2 Axis Origin Pallet installation error detected; (BPH504/505)
(5201)
120105 TV #2 Axis Origin Pallet detected. (5202)
120106 TV #2 Axis Origin Operation not completed normally. (5203)
120107 TV #2 Axis Origin Zeroing not completed within specified time. (5204)
120108 TV #2 Axis Origin Pallet installation error detected.; ( BPH504/505)
(5401)
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
3.3 Error IDs and Remedial Procedures
0308-003 2-71 AHB01ETRP
Error ID Item Description
120109 TV #2 Axis Origin Pallet detected. (5402)
12010a TV #2 Axis Origin Operation not completed normally. (5403)
12010b TV #2 Axis Origin Zeroing not completed within specified time. (5404)
12010c TV #2 Axis Origin Pallet not detected. (5501)
12010d TV #2 Axis Origin Pallet installation error not detected within specified
time. (5502)
12010e TV #2 Axis Origin Pallet installation error detected before destinatation.
(5601)
12010f TV #2 Axis Origin Pallet not detected. (5701)
120110 TV #2 Axis Origin Operation not completed normally. (5702)
120111 TV #2 Axis Origin Operation not completed within specified time. (5703)
120114 TV #2 Axis Origin Rack shutter not closed within specified time. (5704)
120115 TV #2 Axis Origin Origin detected after end of zeroing operation.
(BPH511) (5901)
120117 TV #2 Axis Origin Operation not completed normally. (5902)
120118 TV #2 Axis Origin The limit sensors (BPH513) detected the limit. (5903)
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
120201 TV #2 Axis Timing
120301 TV #2 Axis Data
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
3.3 Error IDs and Remedial Procedures
0206-002 2-72 AHB01ETRP
Error ID Item Description
120401 TV #2 Axis Limit
120402 TV #2 Axis Limit
(Cause 1) The X1 axis might have overrun due to generation of noises, overcurrent, etc.
The sensor may be defective.
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
120601 TV #2 Axis Interlock Driver Alarm
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service per-
sonnel for the remedy.
120602 TV #2 Axis Interlock Pick-Up Error Detection (Upper, 16.5 mm or more);
BPH518
120603 TV #2 Axis Interlock Pick-Up Error Detection (Lower, 8.0 mm or more);
BPH517
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Remove the mispicked component on the tray.
120604 TV #2 Axis Interlock Pass-line Interlock
120605 TV #2 Axis Interlock Pick-Up Error Detection (Upper, 28.0 mm or more);
BPH522
120606 TV #2 Axis Interlock
120607 TV #2 Axis Interlock
120608 TV #2 Axis Interlock Overload Safety Shutoff Detection (Safety Relay)
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
3.3 Error IDs and Remedial Procedures
0308-004 2-73 AHB01ETRP