4OM-1075-002 - 第169页

Error ID Item Description 12f00e T V # 2 Axis Operation Error 12f00f T V # 2 Axis Operation Error (Cause 1) Self-Diagnostics Error Message (Remedy 1) Zero all axes and re-start the operation. When the machine cannot be s…

100%1 / 299
Error ID Item Description
12300c TV #2 Precheck
12300d TV #2 Precheck
12300e TV #2 Precheck
12300f TV #2 Precheck
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
12f001 TV #2 Axis Operation Error Tray No. Error
12f002 TV #2 Axis Operation Error Step No. Error
12f003 TV #2 Axis Operation Error Designated speed error.
12f004 TV #2 Axis Operation Error Destination error
12f005 TV #2 Axis Operation Error Destination error
12f006 TV #2 Axis Operation Error Overtime in Operation
12f007 TV #2 Axis Operation Error A limit error or a component pickup error was de-
tected during movement.
12f008 TV #2 Axis Operation Error Emergency stop
12f009 TV #2 Axis Operation Error A component pickup error was detected during
movement.
12f00a TV #2 Axis Operation Error
12f00b TV #2 Axis Operation Error
12f00c TV #2 Axis Operation Error
12f00d TV #2 Axis Operation Error
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
3.3 Error IDs and Remedial Procedures
0308-003 2-76 AHB01ETRP
Error ID Item Description
12f00e TV #2 Axis Operation Error
12f00f TV #2 Axis Operation Error
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
130101 Elevator #1 Axis Origin Encoder origin was not detected.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
130102 Elevator #1 Axis Origin Origin sensor (slide) was not detected.
130103 Elevator #1 Axis Origin Origin sensor (slide) and Limit error has been de-
tected.
(Cause 1) The backup U/D axis might have overrun due to a defective sensor, a broken cable,
generation of noises, or overcurrent.
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
130104 Elevator #1 Axis Origin Feedback value is indefinite.
130105 Elevator #1 Axis Origin Elevator #1 axis is not at origin.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
3.3 Error IDs and Remedial Procedures
0206-002 2-77 AHB01ETRP
Error ID Item Description
130201 Elevator #1 Axis Timing Task has not been completed unable to continue.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
130301 Elevator #1 Axis Data The driver data was detected outside of the possible
range.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
130401 Elevator #1 Axis Limit (+) Limit error has been detected.
130402 Elevator #1 Axis Limit (-) Limit error has been detected.
(Cause 1) The X1 axis might have overrun due to generation of noises, overcurrent, etc.
The sensor may be defective.
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
130502 Elevator #1 Axis Servo Alarm Parameter breakdown.
130503 Elevator #1 Axis Servo Alarm Main circuit encoder error.
130504 Elevator #1 Axis Servo Alarm Parameter setting error.
130505 Elevator #1 Axis Servo Alarm Combination error.
130510 Elevator #1 Axis Servo Alarm Overcurrent or heat sink overheated.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
3.3 Error IDs and Remedial Procedures
0206-002 2-78 AHB01ETRP