4OM-1075-002 - 第183页
Error ID Item Description 140701 Elevator #2 Axis Interlock Driver alarm (interlock board) 140702 Elevator #2 Axis Interlock Pallet installation error detected (on traverse side). 140703 Elevator #2 Axis Interlock Rack s…

Error ID Item Description
140601 Elevator #2 Axis Servo Error Emergency stop.
140602 Elevator #2 Axis Servo Error Emergency stop (EXT1).
140603 Elevator #2 Axis Servo Error Encoder error.
140604 Elevator #2 Axis Servo Error C phase distance alarm.
140605 Elevator #2 Axis Servo Error Mechatrolink wire cut.
140606 Elevator #2 Axis Servo Error Location timeout.
140607 Elevator #2 Axis Servo Error Position pulse error overflow error.
140608 Elevator #2 Axis Servo Error Software limit (-)
140609 Elevator #2 Axis Servo Error Software limit (+)
14060a Elevator #2 Axis Servo Error Illegal parameter.
14060b Elevator #2 Axis Servo Error Servo ON timeout.
14060c Elevator #2 Axis Servo Error Servo off timeout.
14060d Elevator #2 Axis Servo Error System error.
14060e Elevator #2 Axis Servo Error Invalid command.
14060f Elevator #2 Axis Servo Error Error 1 (No Factor)
140610 Elevator #2 Axis Servo Error Error 2 (No Factor)
140611 Elevator #2 Axis Servo Error Emergency stop (EXT1) when servo on
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
3.3 Error IDs and Remedial Procedures
0206-002 2-90 AHB01ETRP

Error ID Item Description
140701 Elevator #2 Axis Interlock Driver alarm (interlock board)
140702 Elevator #2 Axis Interlock Pallet installation error detected (on traverse side).
140703 Elevator #2 Axis Interlock Rack shutter opened (operator side)
140704 Elevator #2 Axis Interlock Overload safety shutoff detection (safety relay)
140705 Elevator #2 Axis Interlock Maintenance cover opened.
140706 Elevator #2 Axis Interlock Pallet chuck opened during elevator movement.
140707 Elevator #2 Axis Interlock Elevator started working during traverse movement.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
141001 Elevator #2 Axis Check to Move Zeroing not completed within specified time. (Current
Position Indefinite)
141002 Elevator #2 Axis Check to Move Pallet not drawn normally.
141003 Elevator #2 Axis Check to Move Multi-layer tray feeder door opened. (K504)
141004 Elevator #2 Axis Check to Move Safty relay off; K502
141005 Elevator #2 Axis Check to Move Pallet installation error detected (on operator or
drawing side).; BPH504/505
141006 Elevator #2 Axis Check to Move Rack shutter opened.; BPS502/504
141007 Elevator #2 Axis Check to Move Pallet chuck opened.; BPS512
141008 Elevator #2 Axis Check to Move L1 Axis Zeroing not completed
141009 Elevator #2 Axis Check to Move
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
3.3 Error IDs and Remedial Procedures
0206-002 2-91 AHB01ETRP

Error ID Item Description
14100a Elevator #2 Axis Check to Move
14100b Elevator #2 Axis Check to Move Pallet detected.; BPS514
14100c Elevator #2 Axis Check to Move
14100d Elevator #2 Axis Check to Move
14100e Elevator #2 Axis Check to Move Drawing step No. indefinite. Remove the pallet.
14100f Elevator #2 Axis Check to Move Incorrect No. of Drawing Step
142001 Elevator #2 Axis Check to Move
142002 Elevator #2 Axis Check to Move
142003 Elevator #2 Axis Check to Move
142004 Elevator #2 Axis Check to Move
142005 Elevator #2 Axis Check to Move Pallet installation error detected on operator side.;
BPH505
142006 Elevator #2 Axis Check to Move Rack shutter closed.; BPS501/503
142007 Elevator #2 Axis Check to Move
142008 Elevator #2 Axis Check to Move
142009 Elevator #2 Axis Check to Move
14200a Elevator #2 Axis Check to Move
14200b Elevator #2 Axis Check to Move
14200c Elevator #2 Axis Check to Move
14200d Elevator #2 Axis Check to Move
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
3.3 Error IDs and Remedial Procedures
0206-002 2-92 AHB01ETRP