4OM-1075-002 - 第192页
Error ID Item Description 600501 Safety Circuit Activated 600502 Safety Circuit Activated Load Beam Power ON Out of Time Limit 600503 Safety Circuit Activated 600504 Safety Circuit Activated 600505 Safety Circuit Activat…

Error ID Item Description
600201 Beam Power Shutoff
600202 Beam Power Shutoff Load Beam Power ON Out of Time Limit
600203 Beam Power Shutoff
600301 B Beam Power Shutoff
600302 B Beam Power Shutoff
600303 B Beam Power Shutoff
600401 Interlock Error
600402 Interlock Error
600403 Interlock Error
600404 Interlock Error
600405 Interlock Error
600406 Interlock Error
600407 Interlock Error
600408 Interlock Error
600409 Interlock Error
60040a Interlock Error
60040b Interlock Error
60040c Interlock Error
60040d Interlock Error
60040e Interlock Error
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
3.3 Error IDs and Remedial Procedures
0206-002 2-98 AHB01ETRP

Error ID Item Description
600501 Safety Circuit Activated
600502 Safety Circuit Activated Load Beam Power ON Out of Time Limit
600503 Safety Circuit Activated
600504 Safety Circuit Activated
600505 Safety Circuit Activated
610101 Nozzle Allocation No nozzle is specified in the current pattern program
data.
(Cause 1) The nozzles to be used in the current pattern program data are not prepared.
(Remedy 1) Set the nozzles for the production model in the nozzle stocker data and perform
the program change operation.
610102 Nozzle Allocation
610201 Recognition Internal Data XXXX
610301 Component Recognition Data
610302 Component Recognition Data
610401 Nozzle Replace Data No effective step exists in the current pattern pro-
gram when the nozzle change data is created.
610402 Nozzle Replace Data Adequate memory capacity was not left when the
nozzle change data was created.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service per-
sonnel for the remedy.
610403 Nozzle Replace Data Control Commands "-" were not specified for both
primary and secondary nozzles in the component
library data.
(Cause 1) The correct parameters are not set in the "Control command" text boxes of the
labels "Selected nozzle #1" and "Selected nozzle #2" in the component library data.
(Remedy 1) Set correct parameters.
3.3 Error IDs and Remedial Procedures
0308-003 2-99 AHB01ETRP

0308-002 2-99-1 AHB01ETRP
3.3 Error IDs and Remedial Procedures
Error ID Item Description
610404 Nozzle Replace Data There is no nozzle to be used in the nozzle stocker
data.
(Cause 1) See the Description.
(Remedy 1) Set the nozzles to be used in the nozzle stocker data.
610405 Nozzle Replace Data Although the same type of nozzles are specified for
the pick-up priority and simulataneous pick-up steps,
only one nozzle exists.
(Cause 1) See the Description.
(Remedy 1)
Set two nozzles or more to be used for the "Simultaneous Pick-Up" and
"Pick-Up Priority" steps in the nozzle stocker data.
610406 Nozzle Replace Data All nozzle holder are bypass-specified.
610407 Nozzle Replace Data
610501 Internal Data The offset data (internal data) is replaced with unex-
pected data (value).
(Cause 1) See the Description.
(Remedy) Open the window for offset editing and save the data again.
610601 Cmpnt Library Data Error Error in "Contorol Data Select noz #1 Beam (X/Y)".
610602 Cmpnt Library Data Error Error in "Contorol Data Select noz #1 Pu descent
dclr 1".
610603 Cmpnt Library Data Error Error in "Contorol Data Select noz #1 Pu descent
dclr 2".
610604 Cmpnt Library Data Error Error in "Contorol Data Select noz #1 Pu descent
dclr 2 stroke".
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service per-
sonnel for the remedy.