Error ID Item Description
680401 Comp. Recog Error
(Cause 1) "Recognition Error" was detected as the result of the recognition with the compo-
nent recognition camera.
Note: The same number of pick-up errors as specified in the component library
data (the parameter in the "2" text box of "Error process" in the "Control
Data" tab sheet) occurred continuously at the same feeder No.
(Remedy 1) Follow the steps below to reset the machine to the normal condition.
(1) Press the [RETURN] button.
(2) Check the cause of the pick-up error and take correct measures.
When a component shortage error has occurred, replenish components.
When a component is not picked up correctly, remove the component.
When a feeder is loaded with wrong components, re-load the feeder with
correct components.
If wrong parameters are set in the component library data, correct them.
(3) After taking the required countermeasures, re-start the production.
680501 Shortage of Component
(Cause 1)
(Remedy 1)
680601 V.Bend Detection Error
Refer to the instruction manual of special sperifications for V. bent detection for Cause and
Rmedy.
680701 Shortage of Component
(Alternated Feeder)
(Cause 1)
(Remedy 1)
680a01 Auto Recovery Pause
(Cause 1)
(Remedy 1)
3.3 Error IDs and Remedial Procedures
0206-002 2-102 AHB01ETRP
Error ID Item Description
690101 Nozzle Attach Nozzle stocker A1 not opened completely within
specified time.
690102 Nozzle Attach Nozzle stocker A2 not opened completely within
specified time.
690103 Nozzle Attach Nozzle stocker B1 not opened completely within
specified time.
690104 Nozzle Attach Nozzle stocker B2 not opened completely within
specified time.
690105 Nozzle Attach Nozzle stocker A1 not closed completely within
specified time.
690106 Nozzle Attach Nozzle stocker A2 not closed completely within
specified time.
690107 Nozzle Attach Nozzle stocker B1 not closed completely within
specified time.
690108 Nozzle Attach Nozzle stocker B2 not closed completely within
specified time.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
690109 Nozzle Attach Nozzle not attached.
(Cause 1) The nozzles set in the nozzle stockers are different from those specified in the
nozzle stocker data.
(Remedy 1) Check the nozzle stocker data and attach the nozzles correctly.
When the nozzle stocker data is wrong, be sure to correct the data.
69010a Nozzle Attach Nozzle length error was detected.
69010b Nozzle Attach
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
0206-003 2-103 AHB01ETRP
3.3 Error IDs and Remedial Procedures
Error ID Item Description
690201 Nozzle Store Nozzle stocker A1 not opened completely within
specified time.
690202 Nozzle Store Nozzle stocker A2 not opened completely within
specified time.
690203 Nozzle Store Nozzle stocker B1 not opened completely within
specified time.
690204 Nozzle Store Nozzle stocker B2 not opened completely within
specified time.
690205 Nozzle Store Nozzle stocker A1 not closed completely within
specified time.
690206 Nozzle Store Nozzle stocker A2 not closed completely within
specified time.
690207 Nozzle Store Nozzle stocker B1 not closed completely within
specified time.
690208 Nozzle Store Nozzle stocker B2 not closed completely within
specified time.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
690209 Nozzle Store Nozzle not stored.
(Cause 1) The nozzles set in the nozzle stockers are different from those specified in the
nozzle stocker data.
(Remedy 1) Check the nozzle stocker data and attach the nozzles correctly.
When the nozzle stocker data is wrong, be sure to correct the data.
69020a Nozzle Store
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
3.3 Error IDs and Remedial Procedures
0206-003 2-104 AHB01ETRP