0308-002 2-105-3 AHB01ETRP 3.3 Error IDs and Remedial Procedures Error ID Item Description 6b3021 V .Bend Detection Operation Error T erminal Detection Error! W rong Measurement Data (Completely Dark Image). (3020) 6b303…

Error ID Item Description
6b2041 V.Bend Detection Operation Error Measurement Start Signal Not Recognized. (2040)
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Check the lead coplanarity unit PC and the cable connected to the main body.
(Measurement Start Signal)
6b2051 V.Bend Detection Operation Error Illegal Command Parameter. (2050)
6b2061 V.Bend Detection Operation Error Unknown Reference Component Data. (2060)
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Shut down the machine and power it up again.
6b2071 V.Bend Detection Operation Error Improper Measurement Mode. (2070)
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Make the measurement in the normal mode.
6b3001 V.Bend Detection Operation Error Coplanarity Error! (3000)
6b3011 V.Bend Detection Operation Error Terminal Misregistration Error! (3010)
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service per-
sonnel for the remedy.
0308-002 2-105-2 AHB01ETRP
3.3 Error IDs and Remedial Procedures

0308-002 2-105-3 AHB01ETRP
3.3 Error IDs and Remedial Procedures
Error ID Item Description
6b3021 V.Bend Detection Operation Error Terminal Detection Error! Wrong Measurement Data
(Completely Dark Image). (3020)
6b3031 V.Bend Detection Operation Error Terminal Detection Error! Error in Number of Ex-
tracted Terminals (labeling). (3030)
6b3041 V.Bend Detection Operation Error Terminal Detection Error! Terminal Allocation Error
(Impossible Terminal Arrangement Detection). (3040)
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Check the component size and thickness data.
6b3061 V.Bend Detection Operation Error Terminal Detection Error! Edge Detection Error
(Impossible Edge Detection of Gauge during
Installation Calibration). (3060)
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Check the pick-up condition of the calibration gauge and how the device is
mounted
6b3071 V.Bend Detection Operation Error Coplanarity Error! (3070)
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service per-
sonnel for the remedy.
6b3081 V.Bend Detection Operation Error Impaired Terminal (Nicked) Error. (3080)
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Check the lead, ball position, and quantity data.

Error ID Item Description
6b3091 V.Bend Detection Operation Error 2pinTr Error! (ONE all NG)
6b30a1 V.Bend Detection Operation Error 2pinTr Error! (PIN1 upper)
6b30b1 V.Bend Detection Operation Error 2pinTr Error! (PIN1 lower)
6b30c1 V.Bend Detection Operation Error 2pinTr Error! (PIN2 upper)
6b30d1 V.Bend Detection Operation Error 2pinTr Error! (PIN2 lower)
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service per-
sonnel for the remedy.
6b3101 V.Bend Detection Operation Error Reference Plane Flapping Error. (3100)
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service per-
sonnel for the remedy.
3.3 Error IDs and Remedial Procedures
0308-002 2-105-4 AHB01ETRP