4OM-1075-002 - 第210页

Error ID Item Description 6b31 1 1 V .Bend Detection Operation Error T erminal Detection Error! Out of Edge Position Measurable Range ("Near" Side). (31 10) 6b3121 V .Bend Detection Operation Error T erminal De…

100%1 / 299
Error ID Item Description
6b3091 V.Bend Detection Operation Error 2pinTr Error! (ONE all NG)
6b30a1 V.Bend Detection Operation Error 2pinTr Error! (PIN1 upper)
6b30b1 V.Bend Detection Operation Error 2pinTr Error! (PIN1 lower)
6b30c1 V.Bend Detection Operation Error 2pinTr Error! (PIN2 upper)
6b30d1 V.Bend Detection Operation Error 2pinTr Error! (PIN2 lower)
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service per-
sonnel for the remedy.
6b3101 V.Bend Detection Operation Error Reference Plane Flapping Error. (3100)
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service per-
sonnel for the remedy.
3.3 Error IDs and Remedial Procedures
0308-002 2-105-4 AHB01ETRP
Error ID Item Description
6b3111 V.Bend Detection Operation Error Terminal Detection Error! Out of Edge Position
Measurable Range ("Near" Side). (3110)
6b3121 V.Bend Detection Operation Error Terminal Detection Error! Out of Edge Position
Measurable Range ("Far" Side). (3120)
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) ) Check the component thickness and V-bend unit height offset data.
6b3131 V.Bend Detection Operation Error Sampling Error ("DARK" Alarm). (3130)
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) ) Decrease the dark level (dlv) of the component library data.
6b3141 V.Bend Detection Operation Error Sampling Error ("BRIGHT" Alarm). (3140)
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) ) Decrease the laser power (lpw) of the component library data.
6b9001 V.Bend Detection System Error Sysyem error. (9000)
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Shut down the machine and power it up again.
6b9011 V.Bend Detection System Error
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service per-
sonnel for the remedy.
3.3 Error IDs and Remedial Procedures
0308-002 2-105-5 AHB01ETRP
3.3 Error IDs and Remedial Procedures
Error ID Item Description
6c0101 Operator's Error
6c0102 Operator's Error
6c0103 Operator's Error
6c0104 Operator's Error The operation mode switch was changed over with
the machine in a mode other than "STOP".
6c0105 Operator's Error The operation mode switch on the invalid side was
changed over.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Set the [OPERATION] switch to the "RUN" side and zero all axes. Then, re-start
the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
6c0106 Operator's Error The operation mode switch was changed over with
the safety door being open.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Set the [OPERATION] switch back to the "SETUP" side and continue the
operation.
6c0107 Operator's Error
6c0108 Operator's Error
6c0109 Operator's Error Zero the L1 axis.
6c010a Operator's Error Zero the L2 axis.
6c010b Operator's Error The specified axis is being zeroed.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Refer to the displayed contents (description) and take proper measures.
Take proper measures. After that, zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
0308-002 2-105-6 AHB01ETRP