4OM-1075-002 - 第218页
Error ID Item Description 6d0501 NC-Axis Offset JIG component not recognized through component recognition camera. 6d0502 NC-Axis Offset JIG component not recognized through component recognition camera. 6d0503 NC-Axis O…

Error ID Item Description
6d0101 P.E.C. Recognition Camera & Beam Recognition error occurred during teaching.
Offset
6d0102 P.E.C. Recognition Camera & Beam Checker mark not recognized on JIG P.C.B.
Offset
6d0103 P.E.C. Recognition Camera & Beam Checker mark not recognized on JIG P.C.B.
Offset
6d0104 P.E.C. Recognition Camera & Beam Checker mark not recognized on JIG P.C.B.
Offset
6d0105 P.E.C. Recognition Camera & Beam Checker mark not recognized on JIG P.C.B.
Offset
6d0201 Component Recognition Camera Recognition error occurred during teaching.
(Fixed) Magnification
6d0301 Component Recognition (Fixed) Recognition error occurred during teaching.
Camera Offset
6d0302 Component Recognition (Fixed) Recognition error occurred during teaching.
Camera Offset
6d0303 Component Recognition (Fixed) Recognition error occurred during teaching.
Camera Offset
6d0304 Component Recognition (Fixed) Recognition error occurred during teaching.
Camera Offset
6d0305 Component Recognition (Fixed) Recognition error occurred during teaching.
Camera Offset
6d0306 Component Recognition (Fixed) Recognition error occurred during teaching.
Camera Offset
6d0401 Head Rotational Center Offset JIG component not recognized through component
recognition camera.
6d0402 Head Rotational Center Offset JIG component not recognized through component
recognition camera.
6d0403 Head Rotational Center Offset JIG component not recognized through component
recognition camera.
6d0404 Head Rotational Center Offset JIG component not recognized through component
recognition camera.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
3.3 Error IDs and Remedial Procedures
0308-004 2-109 AHB01ETRP

Error ID Item Description
6d0501 NC-Axis Offset JIG component not recognized through component
recognition camera.
6d0502 NC-Axis Offset JIG component not recognized through component
recognition camera.
6d0503 NC-Axis Offset JIG component not recognized through component
recognition camera.
6d0550 NC-Axis Offset Sensor is ON.
6d0551 NC-Axis Offset Sensor is OFF. (1)
6d0552 NC-Axis Offset Sensor is OFF. (2)
6d0553 NC-Axis Offset Sensor is OFF. (3)
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
6d0601 Component Recognition Camera Recognition error occurred during teaching.
(Movable) Magnification
6d0701 Component Recognition Camera JIG component not recognized through component
(Movable) Offset recognition camera.
6d0702 Component Recognition Camera JIG component not recognized through component
(Movable) Offset recognition camera.
6d0801 Head Rotation Offset JIG component not recognized through component
recognition camera.
6d0901 Component Recognition Camera Recognition error occurred during teaching.
(Movable) Position Offset
6d0902 Component Recognition Camera
(Movable) Position Offset
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
3.3 Error IDs and Remedial Procedures
0308-003 2-109-1 AHB01ETRP

Error ID Item Description
6d0a01 Nozzle Stocker Position Offset Round mark not recognized.
6d0a02 Nozzle Stocker Position Offset Round mark not recognized.
6d0b01 Feeder Base Offset Round mark not recognized.
6d0b02 Feeder Base Offset Round mark not recognized.
6d0c01 Feeder (A) Offset Round mark not recognized.
6d0c02 Feeder (A) Offset Round mark not recognized.
6d0d01 Feeder (B) Offset Round mark not recognized.
6d0d02 Feeder (B) Offset Round mark not recognized.
6d0e01 Teaching Plate Offset Recognition error occurred during teaching.
6d0e02 Teaching Plate Offset
6d0f01 Teble Offset Checker mark not recognized on JIG P.C.B.
6d0f02 Teble Offset Checker mark not recognized on JIG P.C.B.
6d0f51 Teble Offset
6d0f52 Teble Offset
6d1001 Nozzle Center Offset Recognition error occurred during teaching.
6d1002 Nozzle Center Offset Recognition error occurred during teaching.
6d1003 Nozzle Center Offset
6d1010 Nozzle Center Offset Execute all zero operation.
6d1101 Traverse Offset Round mark not recognized.
6d1102 Traverse Offset Round mark not recognized.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
3.3 Error IDs and Remedial Procedures
0206-003 2-110 AHB01ETRP