4OM-1075-002 - 第231页

0206-001 2-1 13-7 AHB01ETRP Error ID Item Description 6f161b Tray 1 Feeder Zeroing Error The chuck did not close within the specified time. (1602) (Cause 1) Self-Diagnostics Error Message (Remedy 1) Check Sensor BPS512. …

100%1 / 299
Error ID Item Description
6f1613 Tray 1 Feeder Zeroing Error An ejected pallet was detected. (1202)
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Check Sensors BPH504 and BPH505.
6f1614 Tray 1 Feeder Zeroing Error The pallet was not detected. (1203)
6f1615 Tray 1 Feeder Zeroing Error The elevator could not move to the return step
becaue the pallet was not drawn out. (1301)
6f1616 Tray 1 Feeder Zeroing Error The elevator movement to the return step ended in an
error condition. (1302)
6f1617 Tray 1 Feeder Zeroing Error The elevator movement to the return step ended in an
error condition. (1401)
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
6f1618 Tray 1 Feeder Zeroing Error The rack shutter did not open within the specified
time. (1501)
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Check Sensors BPS501 and BPH503.
6f1619 Tray 1 Feeder Zeroing Error The chuck did not open within the specified time.
(1502)
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) ) Check Sensor BPS511.
6f161a Tray 1 Feeder Zeroing Error The rack shutter did not close within the specified
time. (1601)
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Check Sensors BPS502 and BPH504.
3.3 Error IDs and Remedial Procedures
0206-001 2-1 13-6 AHB01ETRP
0206-001 2-1 13-7 AHB01ETRP
Error ID Item Description
6f161b Tray 1 Feeder Zeroing Error The chuck did not close within the specified time.
(1602)
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Check Sensor BPS512.
6f161c Tray 1 Feeder Zeroing Error The rack shutter did not close within the specified
time. (1701)
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Check Sensors BPS502 and BPH504.
6f161d Tray 1 Feeder Zeroing Error The zeroing operation of the traverse ended in an
error condition. (0304)
6f161e Tray 1 Feeder Zeroing Error The zeroing operation of the traverse ended in an
error condition. (1801)
6f161f Tray 1 Feeder Zeroing Error The zeroing operation could not be performed be-
cause the L1 axis was not located at its origin.
(2000)
6f1620 Tray 1 Feeder Zeroing Error The zeroing operation could not be performed be-
cause the L2 axis was not located at its origin.
(2001)
6f1621 Tray 1 Feeder Zeroing Error The zeroing operation could not be performed be-
cause the L1 axis was not located at its origin.
(2100)
6f1622 Tray 1 Feeder Zeroing Error The zeroing operation could not be performed be-
cause the L2 axis was not located at its origin.
(2101)
6f1623 Tray 1 Feeder Zeroing Error A tray was detected at the return position. (1503)
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
6f1624 Tray 1 Feeder Zeroing Error The chuck did not close within the specified time.
(2201)
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Check Sensor BPS512.
3.3 Error IDs and Remedial Procedures
0206-001 2-1 13-8 AHB01ETRP
Error ID Item Description
6f1625 Tray 1 Feeder Zeroing Error The rack shutter did not close within the specified
time. (2301)
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Check Sensors BPS502 and BPS504.
6f1626 Tray 1 Feeder Zeroing Error The elevator movement to the return step ended in an
error condition. (2401)
6f1627 Tray 1 Feeder Zeroing Error The elevator movement to the return step ended in an
error condition. (2501)
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
6f1628 Tray 1 Feeder Zeroing Error Defective Pallet Detection Sensor (BPH514) (1603)
6f1629 Tray 1 Feeder Zeroing Error Defective Pallet Detection Sensor (BPH514) (2601)
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Check Sensor BPH514.
6f162a Tray 1 Feeder Zeroing Error The zeroing operation of the elevator ended in an
error condition. (2701)
6f162b Tray 1 Feeder Zeroing Error The zeroing operation of the elevator ended in an
error condition. (2801)
6f162c Tray 1 Feeder Zeroing Error The zeroing operation of the elevator ended in an
error condition. (2901)
6f162d Tray 1 Feeder Zeroing Error Origin Not Detected by Sensor (3001)
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
3.3 Error IDs and Remedial Procedures