4OM-1075-002 - 第245页

Error ID Item Description 720102 Bank Carriage B Status Error 720103 Bank Carriage B Status Error 720104 Bank Carriage B Status Error 720105 Bank Carriage B Status Error 720106 Bank Carriage B Status Error 720107 Bank Ca…

100%1 / 299
0206-001 2-1 13-20 AHB01ETRP
Error ID Item Description
710101 Bank Carriage A Status Error
710102
710103
710104
710105
710106
710107
710108
710109
71010a
710201 Bank Carriage A Interlock
710202
710203
710204
710205
710301 Bank Carriage A Out of Time Limit
710302
710303
710304
710401 Bank Cariage A Operator's Error
720101 Bank Carriage B Status Error
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
3.3 Error IDs and Remedial Procedures
Error ID Item Description
720102 Bank Carriage B Status Error
720103 Bank Carriage B Status Error
720104 Bank Carriage B Status Error
720105 Bank Carriage B Status Error
720106 Bank Carriage B Status Error
720107 Bank Carriage B Status Error
720108 Bank Carriage B Status Error
720109 Bank Carriage B Status Error
72010a Bank Carriage B Status Error
720201 Bank Carriage B Interlock
720202 Bank Carriage B Interlock
720203 Bank Carriage B Interlock
720204 Bank Carriage B Interlock
720205 Bank Carriage B Interlock
720301 Bank Carriage B Out of Time Limit
720302 Bank Carriage B Out of Time Limit
720303 Bank Carriage B Out of Time Limit
720304 Bank Carriage B Out of Time Limit
720401 Bank Carriage B Operator's Error
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
3.3 Error IDs and Remedial Procedures
0206-001 2-1 13-21 AHB01ETRP
Error ID Item Description
750101 Input Conveyor Error P.C.B was taken on Input Conveyor. (2100, 1)
750102 Input Conveyor Error P.C.B was taken on Input Conveyor. (2100, 2)
750201 Input Conveyor Error P.C.B was taken on Input Conveyor. (2110, 1)
750202 Input Conveyor Error P.C.B. removed from Input Conveyor (Outlet).
(2110, 2)
750301 Input Conveyor Error P.C.B was taken on Input Conveyor.(2120,1)
750302 Input Conveyor Error P.C.B was taken on Input Conveyor.(2120,2)
750401 Input Conveyor Error P.C.B was taken on Input Conveyor. (2130, 1)
750501 Input Conveyor Error P.C.B was taken on Input Conveyor. (2131, 1)
750601 Input Conveyor Error P.C.B was taken on Input Conveyor. (2132, 1)
750701 Input Conveyor Error P.C.B was taken on Input Conveyor. (2200, 1)
750702 Input Conveyor Error P.C.B was taken on Input Conveyor. (2200, 2)
750801 Input Conveyor Error P.C.B was taken on Input Conveyor. (2201,1)
750802 Input Conveyor Error P.C.B was taken on Input Conveyor. (2201, 2)
750901 Input Conveyor Error P.C.B was taken on Input Conveyor. (2210, 1)
750a01 Input Conveyor Error P.C.B. xfr to P-cnvr were discontinued before P.C.B.
reached act completed. (2220, 1)
750a02 Input Conveyor Error P.C.B. transfer was not completed by a set time.
(2220, 2)
750b01 Input Conveyor Error P.C.B. xfr to P-cnvr were discontinued before P.C.B.
reached act completed. (2221, 1)
750b02 Input Conveyor Error P.C.B was taken on Input Conveyor. (2221, 2)
750b03 Input Conveyor Error P.C.B. transfer was not completed by a set time.
(2221,3 )
750c01 Input Conveyor Error Input machine send sig turned off before P.C.B.
reached. (2225, 1)
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Remove the improper P.C.B. on the conveyor. After that, zero all axes and re-
start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
3.3 Error IDs and Remedial Procedures
0206-002 2-114 AHB01ETRP