4OM-1075-002 - 第25页
(4) Component Storage Box Fig. 4A15 1.3 Maintenance Spots 0308-004 1-12 AHB01ETRP Before removing the accumulated components from the box, be sure to connect a grounding cable (used to make a connection to ground) to you…

(2) Vacuum System
Fig. 4A13
(3) Scrap Box
Fig. 4A14
1.3 Maintenance Spots
• Do not step on the scrap box.
Otherwise, an injury will result due to breakage of the
scrap box.
0308-004 1-11
AHB01ETRP
CAUTION

(4) Component Storage Box
Fig. 4A15
1.3 Maintenance Spots
0308-004 1-12 AHB01ETRP
Before removing the accumulated components from the
box, be sure to connect a grounding cable (used to make
a connection to ground) to your body. Otherwise, some
components may be damaged by static electricity.
CAUTION

(5) Feeder Base
Fig. 4A16
Fig. 4A17
Fiducial Mark 1W2
Every Week Cleaning
Clean the upper surface of the fiducial
mark with a rag.
(2 places × 3 feeder bases)
0206-002 1-13 AHB01ETRP
1.3 Maintenance Spots