Error ID Item Description 780401 Component Reject Conveyor [B] Component reject conveyor [B] became full. (BPH652) 780402 Component Reject Conveyor [B] Recycle Conveyor Motor ON Time-Out (BPH651) 780403 Component Reject …

100%1 / 299
Error ID Item Description
770a01 Output Conveyor Error P-conveyor error was detected.(4215,1)
770a02 Output Conveyor Error P.C.B. xfr to Out cnvr were discontinued before
P.C.B. reached act completed.(4215,2)
770a03 Output Conveyor Error P.C.B was taken on Output Conveyor(4215,3)
770a04 Output Conveyor Error P.C.B. transfer was not completed by a set
time.(4215,4)
770b01 Output Conveyor Error P.C.B. transfer was not completed by a set
time.(4220,1)
770b02 Output Conveyor Error P.C.B was taken on Output Conveyor(4220,2)
770c01 Output Conveyor Error P.C.B was taken on Output Conveyor.(4230,1)
770d01 Output Conveyor Error Conveyor motor error was detected.(4221,1)
770e01 Output Conveyor Error P.C.B. transfer was not completed by a set
time.(4225,1)
780101 Component Reject Cup [A] Component reject cup [A] became full. (BPH044)
780102 Component Reject Cup [A]
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Remove the components from Component Storage Box A.
780201 Component Reject Cup [B] Component reject cup [B] became full. (BPH044)
780202 Component Reject Cup [B]
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Remove the components from Component Storage Box B.
780301 Component Reject Conveyor [A] Component reject conveyor [A] became full.
(BPH652)
780302 Component Reject Conveyor [A] Recycle Conveyor Motor ON Time-Out (BPH651)
780303 Component Reject Conveyor [A] Emergency Stop
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
3.3 Error IDs and Remedial Procedures
0206-001 2-1 19-2 AHB01ETRP
Error ID Item Description
780401 Component Reject Conveyor [B] Component reject conveyor [B] became full.
(BPH652)
780402 Component Reject Conveyor [B] Recycle Conveyor Motor ON Time-Out (BPH651)
780403 Component Reject Conveyor [B] Emergency Stop
790101 Component Recognition Test
790102 Component Recognition Test
790103 Component Recognition Test
790104 Component Recognition Test
790105 Component Recognition Test
790106 Component Recognition Test
790107 Component Recognition Test
790108 Component Recognition Test
790109 Component Recognition Test
79010a Component Recognition Test
790201 Hysteresis Test The speed reduction data [NC Axis] cannot be
specified because there was a deviation at
"90%DECR" [NC Axis]".
790202 Hysteresis Test The speed reduction data [Z Axis] cannot be speci-
fied because there was a deviation at "90%DECR" [Z
Axis]".
790203 Hysteresis Test The speed reduction data [XY Axis] cannot be
specified because there was a deviation at
"90%DECR" [XY Axis]".
790204 Hysteresis Test
790205 Hysteresis Test
790206 Hysteresis Test
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
3.3 Error IDs and Remedial Procedures
0308-002 2-1 19-3 AHB01ETRP
Error ID Item Description
790207 Hysteresis Test
790208 Hysteresis Test
790209 Hysteresis Test
79020a Hysteresis Test
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
7a0101 Program Error Error in Sequence Controller! Operation Not Secured
7a0201 Program Error Error in Polling Task (CPU2)! Operation Not Secured
7a0202 Program Error Error in Polling Task (CPU3)! Operation Not Secured
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
fe0701 HLS MCB1 Error Communication Time-out
fe0702 HLS MCB1 Error Communication Time-out
fe0801 HLS MCB2 Error Communication Time-out
fe0802 HLS MCB2 Error Communication Time-out
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Turn off the power once.
Turn on the power again and zero all axes. Then, re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
3.3 Error IDs and Remedial Procedures