4OM-1075-002 - 第257页

Error ID Item Description ff0601 Interlock Interrupt Beam Power Shut-off ff0602 Interlock Interrupt Air pressure is too low . ff0603 Interlock Interrupt Emergency stop detection ff0604 Interlock Interrupt Front safety do…

100%1 / 299
Error ID Item Description
790207 Hysteresis Test
790208 Hysteresis Test
790209 Hysteresis Test
79020a Hysteresis Test
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
7a0101 Program Error Error in Sequence Controller! Operation Not Secured
7a0201 Program Error Error in Polling Task (CPU2)! Operation Not Secured
7a0202 Program Error Error in Polling Task (CPU3)! Operation Not Secured
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
fe0701 HLS MCB1 Error Communication Time-out
fe0702 HLS MCB1 Error Communication Time-out
fe0801 HLS MCB2 Error Communication Time-out
fe0802 HLS MCB2 Error Communication Time-out
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Turn off the power once.
Turn on the power again and zero all axes. Then, re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
3.3 Error IDs and Remedial Procedures
0308-003 2-120 AHB01ETRP
Error ID Item Description
ff0601 Interlock Interrupt Beam Power Shut-off
ff0602 Interlock Interrupt Air pressure is too low.
ff0603 Interlock Interrupt Emergency stop detection
ff0604 Interlock Interrupt Front safety door was opened.
ff0605 Interlock Interrupt Rear safety door was opened.
ff0606 Interlock Interrupt CB Alarm
ff0607 Interlock Interrupt Safety Circuit
ff0608 Interlock Interrupt Load Power Shut-off
ff0609 Interlock Interrupt FAN Alarm #1
ff060a Interlock Interrupt FAN Alarm #2
ff060b Interlock Interrupt Safety Door (Front or Rear Unknown)
ff060c Interlock Interrupt Y-Axis Servo Ready Shut-off Detection
ff060d Interlock Interrupt X-Axis Servo Ready Shut-off Detection
ff060e Interlock Interrupt Safety Bar Front Detection
ff060f Interlock Interrupt Safety Bar Rear Detection
ff0610 Interlock Interrupt Safety Bar Detection (Front or Rear Unknown)
ff0611 Interlock Interrupt Beam Step-Out Detection 1
ff0612 Interlock Interrupt Beam Step-Out Detection 2
ff0613 Interlock Interrupt Beam Step-Out Detection (1 or 2 Unknown)
ff0614 Interlock Interrupt Tray Main Body I/F Interlock
ff0615 Interlock Interrupt Tray Main Body I/F Interlock
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
3.3 Error IDs and Remedial Procedures
0308-003 2-121 AHB01ETRP
3.3 Error IDs and Remedial Procedures
Error ID Item Description
ff0616 Interlock Interrupt Beam Power Shut-off
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
0308-002 2-121-1 AHB01ETRP