Error ID Item Description 01 30 2 00000 The transferred magnification does not meet the ----- specifications of the machine. (Cause 1) The magnification exceeding the specified one was transferred. (Remedy 1) Contact our…

4.3 Recognition Error IDs and Remedial Procedures
4.3.1 Recognition Communication and Data Errors
AA BB C DDDDD
Detail Code
Secondary Error Classification
1: Recognition Communication
Data Range Error
2: Input Data Assembly Error
3: Input Data Error
Primary Error Classification
10 to 70: Communication Commands
90: Communication Procedure
91: Command Error
92: Response Error
Classification (01) of Recognition Functions
When an error ID other than the described ones is issued, con-
tact our service personnel for some advice.
Table 4B9
Error ID Item Description
01 ** 1***** Error in Recognition Communication Data -----
(Cause 1) An error was found in the recognition communication data.
(Remedy 1) Contact our service personnel for details.
01 14 3 00000 "Lighing for Ceramic P.C.B." is not Connected! -----
(Cause 1) Failed in confirmation to the connection of the lighting unit for ceramic
boards.
(Remedy 1) Contact our service personnel for some advice.
4.3 Recognition Error IDs and Remedial Procedures
0206-002 2-124 AHB01ETRP

Error ID Item Description
01 30 2 00000 The transferred magnification does not meet the -----
specifications of the machine.
(Cause 1) The magnification exceeding the specified one was transferred.
(Remedy 1) Contact our service personnel for details.
01 30 3 00001 Error in "Camera MAGNIFICATION X or
MAGNIFICATION Y" Data.
(Cause 1) Wrong parameters are set.
(Remedy 1) Set correct parameters.
01 38 2 00000 Unavailable fiducial mark code was set.
01 38 2 00001 "Mark Size D2" is too big, compared with "D1".
01 38 2 00002 "Mark Size D3" is too big, compared with "D1".
01 38 2 00003 "Mark Size D2" is too big, comapred with "D3".
01 38 2 00004 "Window Size" is smaller than "Mark Size".
01 38 2 00005 "Mark Size D2" is not set.
01 38 2 00006 "Mark Size D3" is not set.
01 38 3 00001 Error in "P.C.B Recognition Mark Data MarkSize
D1 or D2 or D3" Data.
01 38 3 00003 Error in "P.C.B Recognition Mark Data Window
Size" Data.
(Cause 1) Wrong parameters are set for the P.E.C. recognition function.
(Remedy 1) Refer to "Section 2 Pattern Program" in "Vol. 3" for details and set cor-
rect parameters.
0206-002 2-125 AHB01ETRP
4.3 Recognition Error IDs and Remedial Procedures

Error ID Item Description
01 39 2 11001 An improper parameter is specified as -----
"Component shape".
01 39 2 11002 "Mold Size Tolerance X" is larger than "Mold -----
Size X".
01 39 2 11003 "Mold Size Tolerance Y" is larger than "Mold -----
Size Y".
01 39 2 11004 "Outward Length Tolerances" are larger than -----
"Outward Length".
01 39 2 12001 The total of "Corner 1 Dim X" and "Corner 4 Dim -----
X" is larger than "Mold Size X".
01 39 2 12002 The total of "Corner 1 Dim Y" and "Corner 2 Dim -----
Y" is larger than "Mold Size Y".
01 39 2 12003 The total of "Corner 2 Dim X" and "Corner 3 Dim -----
X" is larger than "Mold Size X".
01 39 2 12004 The total of "Corner 3 Dim Y" and "Corner 4 Dim -----
Y" is larger than "Mold Size Y".
01 39 2 12005 "Electrode Size" is larger than half of "Mold -----
Size X".
01 39 2 12006 "# of Linear Edges" is improper.
01 39 2 13001 "# of Types" (lead data) is improper. -----
01 39 2 13002 "# of Groups" (lead data) is improper. -----
01 39 2 13003 The total of "# of Leads" (lead data) is too small. -----
01 39 2 13004 "No Detection" is set in all "Insp Condtn" text -----
boxes.
01 39 2 13005 "Lead Type No." in "Lead Group 1" is improper. -----
01 39 2 13006 "Lead Type No." in "Lead Group 2" is improper. -----
01 39 2 13007 "Lead Type No." in "Lead Group 3" is improper. -----
01 39 2 13008 "Lead Type No." in "Lead Group 4" is improper. -----
01 39 2 13009 "Lead Type No." in "Lead Group 5" is improper. -----
01 39 2 13010 "Lead Type No." in "Lead Group 6" is improper. -----
(Cause 1) Wrong parameters are set.
(Remedy 1) Set correct parameters.
4.3 Recognition Error IDs and Remedial Procedures
0206-002 2-126 AHB01ETRP