4OM-1075-002 - 第273页

Error ID Item Description 01 39 3 14216 Error in "Component Library Elctd # of Cols" Data. ----- 01 39 3 14217 Error in "Component Library Elctd # of Rows" Data. ----- 01 39 3 14221 Error in "Com…

100%1 / 299
Error ID Item Description
01 39 3 13219 "Component Library Lead Insp Condtn" -----
Not Supported!
01 39 3 13221 "Component Library Lead Detection -----
Position" Not Supported!
01 39 3 13222 "Component Library Lead Detection Area -----
Designation" Not Supported!
(Cause 1) The data is not supported.
(Remedy 1) Set the supported data.
01 39 3 13223 Error in "Component Library Lead Width Detection -----
Area " Data.
01 39 3 13002 Component Library Lead Type Not Supported!
01 39 3 14101 Error in "Component Library Elctd Type No" Data. -----
(Cause 1) Wrong parameters are set.
(Remedy 1) Set correct parameters.
01 39 3 14111 "Component Library Elctd Shape" Not Supported!
(Cause 1) The data is not supported.
(Remedy 1) Set the supported data.
01 39 3 14112 Error in "Component Library Elctd Dim1" Data. -----
01 39 3 14113 Error in "Component Library Elctd Dim2" Data. -----
01 39 3 14213 Error in "Component Library Elctd Gp Posn X or -----
Y" Data.
01 39 3 14214 Error in "Component Library Elctd Col Pitch" Data. -----
01 39 3 14215 Error in "Component Library Row Pitch" Data. -----
(Cause 1) Wrong parameters are set.
(Remedy 1) Set correct parameters.
0308-003 2-135 AHB01ETRP
4.3 Recognition Error IDs and Remedial Procedures
Error ID Item Description
01 39 3 14216 Error in "Component Library Elctd # of Cols" Data. -----
01 39 3 14217 Error in "Component Library Elctd # of Rows" Data. -----
01 39 3 14221 Error in "Component Library Elctd Missing Elctd -----
No" Data.
01 39 3 14231 Error in "Component Library Elctd Missing Std Col" -----
Data.
01 39 3 14232 Error in "Component Library Elctd Missing Std -----
Row" Data.
01 39 3 14233 Error in "Component Library Elctd # of Missing -----
Cols" Data.
01 39 3 14234 Error in "Component Library Elctd # of Missing -----
Rows" Data.
(Cause 1) Wrong parameters are set.
(Remedy 1) Set correct parameters.
01 39 3 20003 "Component Library Recog Level" Not Supported! -----
(Cause 1) The data is not supported.
(Remedy 1) Set the supported data.
01 39 3 20004 "Component Library Front ltg algo" Not Supported! -----
01 39 3 20005 "Component Library Back ltg algo" Not Supported! -----
(Cause 1) Wrong parameters are set.
(Remedy 1) Set correct parameters.
0206-002 2-136 AHB01ETRP
4.3 Recognition Error IDs and Remedial Procedures
Error ID Item Description
01 39 3 20007 "Component Library View Range Set" Not -----
Supported!
01 39 3 22001 "Component Library Polarity detn" Not Supported! -----
01 39 3 22002 "Component Library Polarity Inspection method" -----
Not Supported!
01 39 3 22003 Error in "Component Library Polarity Detn -----
Inspection Pos X or Y" Data.
01 39 3 22004 Error in "Component Library Polarity Detn -----
Inspection range" Data.
01 39 3 23001 "Component Library Upper/Lower surface detn" -----
Not Supported!
(Cause 1) The data is not supported.
(Remedy 1) Set the supported data.
01 39 3 24102 Error in "Component Library Mold size tolerance -----
X or Y" Data.
(Cause 1) Wrong parameters are set.
(Remedy 1) Set correct parameters.
01 39 3 24201 "Component Library Outward Length detn" Not -----
Supported!
(Cause 1) The data is not supported.
(Remedy 1) Set the supported data.
01 39 3 24202 Error in "Component Library Outward Length tol" -----
Data.
(Cause 1) Wrong parameters are set.
(Remedy 1) Set correct parameters.
01 39 3 25101 "Component Library Lead width detn" Not -----
Supported!
(Cause 1) The data is not supported.
(Remedy 1) Set the supported data.
4.3 Recognition Error IDs and Remedial Procedures
0206-003 2-137 AHB01ETRP