4OM-1075-002 - 第276页

Error ID Item Description 01 39 3 26102 Error in "Component Library Electd Pos tol" Data. ----- (Cause 1) Wrong parameters are set. (Remedy 1) Set correct parameters. 01 39 3 26201 "Component Library Elect…

100%1 / 299
Error ID Item Description
01 39 3 25102 Error in "Component Library Lead width tol" Data. -----
(Cause 1) Wrong parameters are set.
(Remedy 1) Set correct parameters.
01 39 3 25201 "Component Library Lead posn(Latl dir)detn" Not -----
Supported!
(Cause 1) The data is not supported.
(Remedy 1) Set the supported data.
01 39 3 25202 Error in "Component Library Lead posn(Latl dir)tol" -----
Data.
(Cause 1) Wrong parameters are set.
(Remedy 1) Set correct parameters.
01 39 3 25301 "Component Library Lead posn(Long dir)tol" Not -----
Supported!
(Cause 1) The data is not supported.
(Remedy 1) Set the supported data.
01 39 3 25302 Error in "Component Library Lead posn (Long dir) -----
tol" Data.
(Cause 1) Wrong parameters are set.
(Remedy 1) Set correct parameters.
01 39 3 26101 "Component Library Electd Pos detn" Not -----
Supported!
(Cause 1) The data is not supported.
(Remedy 1) Set the supported data.
4.3 Recognition Error IDs and Remedial Procedures
0206-002 2-138 AHB01ETRP
Error ID Item Description
01 39 3 26102 Error in "Component Library Electd Pos tol" Data. -----
(Cause 1) Wrong parameters are set.
(Remedy 1) Set correct parameters.
01 39 3 26201 "Component Library Electd Size detn" Not -----
Supported!
(Cause 1) The data is not supported.
(Remedy 1) Set the supported data.
01 39 3 26202 Error in "Component Library Electd Size tol" Data. -----
(Cause 1) Wrong parameters are set.
(Remedy 1) Set correct parameters.
01 50 1 00000 Cam No. is incorrect -----
01 50 1 00001 Nozzle ID is incorrect -----
01 50 1 00002 Angle is incorrect -----
01 51 1 00000 Cam No. is incorrect -----
01 51 1 00001 Mark No. is incorrect -----
01 51 1 00002 Angle is incorrect -----
01 51 1 00003 P.C.B. Recognition Process ID is incorrect -----
01 51 1 00004 Recognition Method is incorrect -----
01 52 1 00000 Cam No. is incorrect -----
01 52 1 00001 Fdr.No. is incorrect -----
01 52 1 00002 Nozzle ID is incorrect -----
4.3 Recognition Error IDs and Remedial Procedures
0308-004 2-139 AHB01ETRP
Error ID Item Description
01 52 1 00003 Nozzle Position X or Y is incorrect -----
01 52 1 00004 Angle is incorrect -----
01 52 1 00005 Division Take in number is incorrect -----
01 52 1 00006 Divided ID is incorrect -----
01 53 1 00000 Cam No. is incorrect -----
01 53 1 00001 Angle is incorrect -----
01 54 1 00000 Cam No. is incorrect -----
01 54 1 00001 Jig Grid Pitch is incorrect -----
01 55 1 00000 Cam No. is incorrect -----
01 56 1 00000 Cam No. is incorrect -----
01 57 1 00000 Cam No. is incorrect -----
01 57 1 00001 Lighting Unit No. is incorrect -----
01 57 1 00002 Lighting Type is incorrect -----
01 57 1 00003 Nozzle ID is incorrect -----
01 58 1 00000 Teaching Mode is incorrect -----
01 58 1 00001 Cam No. is incorrect -----
01 58 1 00002 Language is incorrect -----
01 58 1 00003 Nozzle ID is incorrect -----
01 58 1 00004 Nozzle Position X is incorrect -----
01 58 1 00005 Nozzle Position Y is incorrect -----
01 58 1 00006 Nozzle Angle is incorrect -----
01 58 1 00007 Cmpnt thickness is incorrect -----
01 58 1 00008 Focus level is incorrect -----
01 58 1 00009 Carrier Data Component Direction is incorrect -----
4.3 Recognition Error IDs and Remedial Procedures
0308-001 2-139-1 AHB01ETRP