4OM-1075-002 - 第277页
Error ID Item Description 01 52 1 00003 Nozzle Position X or Y is incorrect ----- 01 52 1 00004 Angle is incorrect ----- 01 52 1 00005 Division T ake in number is incorrect ----- 01 52 1 00006 Divided ID is incorrect ---…

Error ID Item Description
01 39 3 26102 Error in "Component Library Electd Pos tol" Data. -----
(Cause 1) Wrong parameters are set.
(Remedy 1) Set correct parameters.
01 39 3 26201 "Component Library Electd Size detn" Not -----
Supported!
(Cause 1) The data is not supported.
(Remedy 1) Set the supported data.
01 39 3 26202 Error in "Component Library Electd Size tol" Data. -----
(Cause 1) Wrong parameters are set.
(Remedy 1) Set correct parameters.
01 50 1 00000 Cam No. is incorrect -----
01 50 1 00001 Nozzle ID is incorrect -----
01 50 1 00002 Angle is incorrect -----
01 51 1 00000 Cam No. is incorrect -----
01 51 1 00001 Mark No. is incorrect -----
01 51 1 00002 Angle is incorrect -----
01 51 1 00003 P.C.B. Recognition Process ID is incorrect -----
01 51 1 00004 Recognition Method is incorrect -----
01 52 1 00000 Cam No. is incorrect -----
01 52 1 00001 Fdr.No. is incorrect -----
01 52 1 00002 Nozzle ID is incorrect -----
4.3 Recognition Error IDs and Remedial Procedures
0308-004 2-139 AHB01ETRP

Error ID Item Description
01 52 1 00003 Nozzle Position X or Y is incorrect -----
01 52 1 00004 Angle is incorrect -----
01 52 1 00005 Division Take in number is incorrect -----
01 52 1 00006 Divided ID is incorrect -----
01 53 1 00000 Cam No. is incorrect -----
01 53 1 00001 Angle is incorrect -----
01 54 1 00000 Cam No. is incorrect -----
01 54 1 00001 Jig Grid Pitch is incorrect -----
01 55 1 00000 Cam No. is incorrect -----
01 56 1 00000 Cam No. is incorrect -----
01 57 1 00000 Cam No. is incorrect -----
01 57 1 00001 Lighting Unit No. is incorrect -----
01 57 1 00002 Lighting Type is incorrect -----
01 57 1 00003 Nozzle ID is incorrect -----
01 58 1 00000 Teaching Mode is incorrect -----
01 58 1 00001 Cam No. is incorrect -----
01 58 1 00002 Language is incorrect -----
01 58 1 00003 Nozzle ID is incorrect -----
01 58 1 00004 Nozzle Position X is incorrect -----
01 58 1 00005 Nozzle Position Y is incorrect -----
01 58 1 00006 Nozzle Angle is incorrect -----
01 58 1 00007 Cmpnt thickness is incorrect -----
01 58 1 00008 Focus level is incorrect -----
01 58 1 00009 Carrier Data Component Direction is incorrect -----
4.3 Recognition Error IDs and Remedial Procedures
0308-001 2-139-1 AHB01ETRP

Error ID Item Description
01 58 1 00010 Pickup pos correction X is incorrect -----
01 58 1 00011 Pickup pos correction Y is incorrect -----
01 58 1 00012 Start Mode is incorrect -----
01 60 1 00000 Implement Recognition Mode is incorrect -----
01 61 1 00000 Display Mode is incorrect -----
01 61 1 00001 Component Recognition Setting is incorrect -----
01 61 1 00002 Cam No. is incorrect -----
01 61 1 00003 Component ID is incorrect -----
01 61 1 00004 Fdr.No. is incorrect -----
01 61 1 00005 Dsiplay Mode is incorrect -----
01 62 1 00000 Save Operation is incorrect -----
01 62 1 00001 Save Function is incorrect -----
01 62 1 00002 Reognition Save Mode is incorrect -----
01 62 1 00003 Component Recog Setting is incorrect -----
01 62 1 00004 Cam No. is incorrect -----
01 62 1 00005 Component ID is incorrect -----
01 62 1 00006 Fdr.No. is incorrect -----
01 62 1 00007 Resolution of Saved Image is incorrect -----
01 63 1 00000 Saved Image ID is incorrect -----
4.3 Recognition Error IDs and Remedial Procedures
0308-001 2-139-2 AHB01ETRP