4OM-1075-002 - 第281页
(a) Error IDs "*" will be filled with primary error classification and detail codes. (b) When an error ID other than the described ones is issued, contact our service personnel for some advice. T able 4B1 1 Err…

4.3.2 Component Recognition Errors
AA BB C DDD EE
Detail Code : Kinds of Errors (00 to 99)
Detail Code : Kinds of Errors (000 to 999)
Secondary Error Classification:
Error Classification (1 to 99)
Primary Error Classification:
Recognition Algorithm (00 to
99)
Refer to Table 4B10.
Classification of Recognition Functions (02)
Error Classification: Recognition Algorithm
Table 4B10
BB Recognition Algorithm Remarks
00 Others
01 Edge (Rectangle) Front Lighting
02 Corner Back Lighting
03 Corner Front Lighting
04 Edge (General Purpose) Back Lighting
05 Edge (General Purpose) Front Lighting
06 Center of Gravity (Angle Detected) Back Lighting
07 Center of Gravity (Angle Detected) Front Lighting
08 Center of Gravity (Angle Not Detected) Back Lighting
09 Center of Gravity (Angle Not Detected) Front Lighting
10 Line Back Lighting
11 Line Front Lighting
31 Leaded Back Lighting
32 Leaded Front Lighting
33 Multiple Pin Leads (Standard) Back Lighting
34 Multiple Pin Leads (Standard) Front Lighting
35 Multiple Pin Leads (General Purpose) Back Lighting
36 Multiple Pin Leads (General Purpose) Front Lighting
37 Lead (Special) Back Lighting
38 Lead (Special) Front Lighting
39 Lead (Standard 2) Front Lighting
40 Multi-Pin Lead (Standard 2) Back Lighting
41 Multi-Pin Lead (Standard 2) Front Lighting
91 Grid Pattern Front Lighting
92 Grid Pattern Front Lighting
93 Grid Pattern (Divided) Front Lighting
94 Grid Pattern (Divided) Front Lighting
4.3 Recognition Error IDs and Remedial Procedures
0206-002 2-140 AHB01ETRP

(a) Error IDs "*" will be filled with primary error classification
and detail codes.
(b) When an error ID other than the described ones is issued,
contact our service personnel for some advice.
Table 4B11
Error ID Item Description
02 ** 1000 ** Component Missing Component was not found.
(Cause 1) The feeders may be loaded with components different from the specified ones.
(Cause 2) The vacuum suction force is too weak.
(Cause 3) An improper nozzle is selected for the components or vice versa.
(Remedy 1) Check if proper components are used.
(Remedy 2) Check the vacuum pressure.
(Remedy 3) Check the parameters in the nozzle type data and the component library
data.
02 ** 2101 ** Error in Outward Length Inspection Cmponent Outward Length X is incorrect.
02 ** 2102 ** Error in Outward Length Inspection Component Outward Length X is shorter than the
tolerance.
02 ** 2103 ** Error in Outward Length Inspection Component Outward Length X is longer than the
tolerance.
02 ** 2104 ** Error in Outward Length Inspection Component Outward Length Y is incorrect.
02 ** 2105 ** Error in Outward Length Inspection Component Outward Length Y is shorter than the
tolerance.
02 ** 2106 ** Error in Outward Length Inspection Component Outward Length Y is longer than the
tolerance.
02 ** 2107 ** Error in Outward Length Inspection Component Outward Length X or Y is incorrect.
02 ** 2108 ** Error in Outward Length Inspection Component Outward Length X or Y is shorter than
the tolerance.
02 ** 2109 ** Error in Outward Length Inspection Component Outward Length X or Y is longer than
the tolerance.
(Cause 1) Wrong parameters are set in the "X [mm]" and "Y [mm]" text boxes of "Mold
size" and the "Mold size tolerance X [mm]" and "Mold size tolerance Y [mm]"
text boxes for the selected components.
(Remedy 1) Check the selected components and the parameters set in the "X [mm]"
and "Y [mm]" text boxes of "Mold size" and the "Mold size tolerance X
[mm]" and "Mold size tolerance Y [mm]" text boxes for the selected com-
ponents in the component library data.
Correct wrong parameters if they are set in the component library data.
0206-002 2-141 AHB01ETRP
X
Y
Fig. 4B50
4.3 Recognition Error IDs and Remedial Procedures

Error ID Item Description
02 ** 2200 ** Error in Lead Inspection
02 ** 2201 ** Error in Lead Inspection The number of leads is incorrect.
02 ** 2202 ** Error in Lead Inspection The number of leads is small.
02 ** 2203 ** Error in Lead Inspection The number of leads is large.
02 ** 2204 ** Error in Lead Inspection The lead width is incorrect.
02 ** 2205 ** Error in Lead Inspection The lead width is shorter than the tolerance.
02 ** 2206 ** Error in Lead Inspection The lead width is longer than the tolerance.
02 ** 2207 ** Error in Lead Inspection The lead length is incorrect.
02 ** 2208 ** Error in Lead Inspection The lead length is shorter than the tolerance.
02 ** 2209 ** Error in Lead Inspection The lead length is longer than the tolerance.
02 ** 2210 ** Error in Lead Inspection The lead pitch is incorrect.
02 ** 2211 ** Error in Lead Inspection The lead pitch is smaller than the tolerance.
02 ** 2212 ** Error in Lead Inspection The lead pitch is larger than the tolerance.
02 ** 2213 ** Error in Lead Inspection The lead position (LATL DIR) is incorrect.
02 ** 2214 ** Error in Lead Inspection The lead position (LONG DIR) is incorrect.
02 ** 2300 ** Error in Electrode (Ball) Inspection
02 ** 2301 ** Error in Electrode (Ball) Inspection The Electrode (Ball) position is incorrect.
02 ** 2302 ** Error in Electrode (Ball) Inspection There is Electrode (Ball) of the size outside per-
missible value.
02 ** 2401 ** Error in Polarity Detection. Failed in Polarity Detection.
02 ** 2402 ** Error in Polarity Detection. The detected polarity differs from specification.
(Cause 1) The results of the lead inspection differ from the parameters specified in the
component library data for the selected components.
(Remedy 1) Check the leads of the selected component and the component library
data.
Correct wrong parameters if they are set in the component library data.
4.3 Recognition Error IDs and Remedial Procedures
0308-004 2-142 AHB01ETRP