4OM-1075-002 - 第283页
Error ID Item Description 02 ** 2900 ** Picked Posture Error 02 ** 2901 ** Picked Posture Error The pick angular skew is big. 02 ** 2902 ** Picked Posture Error The pick-up position has deviated greatly in X di- rection.…

Error ID Item Description
02 ** 2200 ** Error in Lead Inspection
02 ** 2201 ** Error in Lead Inspection The number of leads is incorrect.
02 ** 2202 ** Error in Lead Inspection The number of leads is small.
02 ** 2203 ** Error in Lead Inspection The number of leads is large.
02 ** 2204 ** Error in Lead Inspection The lead width is incorrect.
02 ** 2205 ** Error in Lead Inspection The lead width is shorter than the tolerance.
02 ** 2206 ** Error in Lead Inspection The lead width is longer than the tolerance.
02 ** 2207 ** Error in Lead Inspection The lead length is incorrect.
02 ** 2208 ** Error in Lead Inspection The lead length is shorter than the tolerance.
02 ** 2209 ** Error in Lead Inspection The lead length is longer than the tolerance.
02 ** 2210 ** Error in Lead Inspection The lead pitch is incorrect.
02 ** 2211 ** Error in Lead Inspection The lead pitch is smaller than the tolerance.
02 ** 2212 ** Error in Lead Inspection The lead pitch is larger than the tolerance.
02 ** 2213 ** Error in Lead Inspection The lead position (LATL DIR) is incorrect.
02 ** 2214 ** Error in Lead Inspection The lead position (LONG DIR) is incorrect.
02 ** 2300 ** Error in Electrode (Ball) Inspection
02 ** 2301 ** Error in Electrode (Ball) Inspection The Electrode (Ball) position is incorrect.
02 ** 2302 ** Error in Electrode (Ball) Inspection There is Electrode (Ball) of the size outside per-
missible value.
02 ** 2401 ** Error in Polarity Detection. Failed in Polarity Detection.
02 ** 2402 ** Error in Polarity Detection. The detected polarity differs from specification.
(Cause 1) The results of the lead inspection differ from the parameters specified in the
component library data for the selected components.
(Remedy 1) Check the leads of the selected component and the component library
data.
Correct wrong parameters if they are set in the component library data.
4.3 Recognition Error IDs and Remedial Procedures
0308-004 2-142 AHB01ETRP

Error ID Item Description
02 ** 2900 ** Picked Posture Error
02 ** 2901 ** Picked Posture Error The pick angular skew is big.
02 ** 2902 ** Picked Posture Error The pick-up position has deviated greatly in X di-
rection.
02 ** 2903 ** Picked Posture Error The pick-up position has deviated greatly in Y di-
rection.
02 ** 2904 ** Picked Posture Error The pick-up position has deviated greatly in X or Y
direction.
(Cause 1) When a component is picked up, the pick-up positions (X and Y) and angle
have shifted greatly from the correct ones.
(Cause 2) A component was turned vertically.
(Remedy 1) Check the components being used and the feeders.
Check if the component library data is correct.
(Remedy 2) Check the components being used and the feeders.
4.3 Recognition Error IDs and Remedial Procedures
0308-004 2-143 AHB01ETRP

Error ID Item Description
02 ** 3100 ** Error in Corner Detection
02 ** 3101 ** Error in Corner Detection More than two corners of a component are hidden
by the protruded nozzle.
02 ** 3102 ** Error in Corner Detection Corner Not Detected.
(Cause 1) The pick-up position has shifted from the specified one in the X direction.
Fig.4B51
(Cause 2) The tapered part of the vacuum nozzle end or the diffusion plate is stained.
Fig.4B52
(Remedy 1) Check the components and the feeders.
(Remedy 2) Clean the vacuum nozzle end or the diffusion plate.
02 ** 3200 ** Error in Center of Gravity Detection
02 ** 3201 ** Error in Center of Gravity Detection The component shape (size) is not applicable.
02 ** 3202 ** Error in Center of Gravity Detection Failed in Corner Detection.
02 ** 3203 ** Error in Center of Gravity Detection Failed in Center of Gravity Detection.
(Cause 1) The selected component does not match the nozzle.
(Cause 2) The component is bent due to weak vacuum suction force.
(Remedy 1) Check the selected component and the vacuum nozzle.
(Remedy 2) Check the vacuum pressure.
4.3 Recognition Error IDs and Remedial Procedures
Vacuum Nozzle
Component
Dirty Spots
Component
Vacuum Nozzle
0308-001 2-143-1 AHB01ETRP