4OM-1075-002 - 第34页

Fig. 4A26 1.3 Maintenance Spots 0308-004 1-21 AHB01ETRP Nozzle Change Cam 1Y1 Y early Replacement Replace the cam with a new one every year . Note: When the nozzle change cam is worn out, a nozzle change error , etc., wi…

100%1 / 299
0308-004 1-20 AHB01ETRP
1.3 Maintenance Spots
Ball Screw 3M6
Every 3 Months Cleaning and Lubrication (DAPHNE EPONEX GREASE No. 1)
Follow the steps below for the lubrication.
1. Turn on the power supply and the air source of the machine.
2. Store all nozzles in the nozzle stockers.
3. Open the "Zeroing Opn." tab sheet and perform the zeroing operation for all devices.
(Operation Sequence: [MAINT.] Button [MNL OPN.] Button "Zeroing Opn." Tab)
4. Open the "Manual Axis Opn." tab sheet and move the heads to the following positions.
(Operation Sequence: [MAINT.] Button [MNL OPN.] Button "Manual Axis Opn." Tab)
Beam X1 Axis: -500 mm (-500000 P)
Beam X2 Axis: -880 mm (-880000 P)
Beam Y Axis: -880 mm (-800000 P)
Head #1 Up/Down Axis: +25 mm (+10000 P)
Head #2 Up/Down Axis: +25 mm (+10000 P)
5. Turn off the power supply and the air source of the machine.
6. Inject a proper amount of "DAPHNE EPONEX GREASE No. 1" from the grease nipples of
Heads #1 and #2.
Use the U+N-type attachment.
7. Turn on the power supply and the air source of the machine.
8. Move the heads up and down to smooth out the grease.
9. Turn off the power supply and the air source of the machine.
10. Wipe off the grease collected at the lower area of the ball screw.
* Take ample care not to leave the waste threads after cleaning.
* Use the U- and S-type attachments.
Grease should be applied every 3 months after the initial month.
U Type S Type
Nipple
Fig. 4A25
Don't do any cleaning and lubrication work with the
power turned "ON".
Be sure to turn off the power before starting any
cleaning and lubrication work.
When the machine malfunctions, you may be
trapped in the moving mechanism and it may re-
sult in a major injury.
Note that only one person should be in
charge of lubrication work.
DANGER
Fig. 4A26
1.3 Maintenance Spots
0308-004 1-21 AHB01ETRP
Nozzle Change Cam 1Y1
Yearly Replacement
Replace the cam with a new one every
year.
Note: When the nozzle change cam is worn
out, a nozzle change error, etc., will
occur, making it impossible to perform
the automatic operation.
Note: Refer to "1.4 Maintenance Method"
for the replacement.
Nozzle Change Cam 1M5
Every Month Lubrication
(DAPHNE EPONEX GREASE No. 1)
Wipe off old grease with a rag and apply a
small amount of new grease with a cotton
swab, etc.
Greasing Spot
0308-001 1-21-1 AHB01ETRP
1.3 Maintenance Spots
Nozzle Shaft 3M13
Every 3 Months Cleaning
Detach the nozzle shaft and blow air to
remove dirt and dust from the shaft.
Note: When the nozzle shaft is heavily
stained, detach the shaft and clean it
with an ultrasonic cleaner or a rag
soaked in alcohol.
If alcohol is used with the shaft being
attached, alcohol adhesion might
cause the diffusion plate to crack.
Refer to "1.4 Maintenance Method"
for how to detach the nozzle shaft.
Nozzle Clamp Spring 1Y2
Yearly Replacement
Replace the spring with a new one every
year.
Note: If the nozzle clamp spring is not
replaced with a new one, a nozzle
change error, etc., will occur, making
difficult the sequence of automatic
operations.
Note: Refer to "1.4 Maintenance Method"
for the replacement.
Fig. 4A26-1