4OM-1075-002 - 第78页
1.3.2 List of Check Messages T able 4B1-7 Error ID Display Section A Display Section B 800501 Alarm for Shortage Few components to feed. of Component 800601 Shortage of Compo- Few components to feed. nent (Tray Step) (Co…

*2 Display Section A
Displayed is the outline of the machine information.
*3 Display Section B
Displayed are the details of the machine information.
*4 [OK] Button
When pressed, this button closes the "Machine Information" win-
dow.
*5 [Clear Alarm] Button
When pressed, this button cancels an alarm (sound) only.
1.3 Machine lnformation
0308-001 2-3-8 AHB01ETRP

1.3.2 List of Check Messages
Table 4B1-7
Error ID Display Section A Display Section B
800501 Alarm for Shortage Few components to feed.
of Component
800601 Shortage of Compo- Few components to feed.
nent (Tray Step)
(Contents) Self-Diagnostics Error Message
(Description) The automatic operation will stop soon due to component shortage.
Prepare for component replenishment.
800701 Product Information Finished Product Interval :
800702 Product Information Auto Run Interval :
800703 Product Information Nozzle Usage Interval :
800801 Machine Interface No signal from furnace.
Signal
800901 Machine Interface
Signal
800a01 Operate Information
800b01 Automatic Feeder
Axis adjustment
limit soft
(Contents) Self-Diagnostics Error Message
(Description) Confirm the displayed contents.
800c01 Alarm for
Maintenance
(Contents) Self-Diagnostics Error Message
(Description) Follow the displayed instructions for maintenance work.
1.3 Machine lnformation
0308-001 2-3-9 AHB01ETRP

Error ID Display Section A Display Section B
801001 V.Bend Detection Retrial was made after the detection height was changed to
Recovery Mode "Higher".
801002 V.Bend Detection Retrial was made after the detection height was changed to
Recovery Mode "Lower".
801003 V.Bend Detection Retrial was made after the dark cut level was decreased.
Recovery Mode
801004 V.Bend Detection Retrial was made after the laser power was decreased.
Recovery Mode
801005 V.Bend Detection Retrial was made in the high accuracy mode.
Recovery Mode
(Contents) The lead coplanarity detection was made again.
(Description) Confirm the displayed contents.
801101 Product Restart Restart production with semi-auto(after specified step) mode.
801102 Product Restart Restart production with warm start mode.
801201 Semi-auto (continue) Production operation was interrupted for the state where P.C.B.
start mode auto before component are placed exists on positioning section.
change
801301 Warm start mode Operation was canceled for the state where the P.C.B. in the middle
auto change of component placing is on positioning section.
801401 Information Data was changed during machine worked. The changed data is
not reflected in operation until it stops or interrupts operation.
80f001 Operate Information Start Power ON sequence.
etc.
80f002 Operate Information Start zeroing.
etc.
80f003 Operate Information Ready button OFF (cover lock OFF).
etc.
80f004 Operate Information Count information
etc.
80f020 System Information Watch. Dog.Timer UP
(Contents) Self-Diagnostics Error Message
(Description) Confirm the displayed contents.
1.3 Machine lnformation
0308-001 2-3-10 AHB01ETRP