General Inspection Methodology 10-49
7. Check the BGA group parameters and make sure the binary threshold works for current
slice. The binary threshold of the BGA group algorithm for 3D slices and 2D images are
not always the same.
8. Switch to slice -15, use copy “IB to current slice” function and create all inspection boxes
for slice -15. For BGA group algorithms, since the ball size is smaller, we normally apply
15% (sometimes 12%) for the ball size check. The binary threshold will also be different
and needs to be re-adjusted. For BGA pin inspection algorithm, it is important to the ball
diameter for slice 0 and slice -15 to different number. After slice -15 is done, do the same
thing for slice 15. Normally ball sizes for slice 15 and -15 will be about the same, which
leads to similar parameter values for these two slices. Remember to update package and
part library at the end. This way a new package for 3D BGA inspection is created.
9. For BGA mounted on bottom side, depends on the board thickness the middle layer is
normally set to a negative number, and the other two slices are set accordingly. For
example, if the board thickness is 60 mil and the BGA package is programmed under 1”
FOV, we may set the middle slice of the BGA to be slice number -60, and the other two
slices to -45 and -75, respectively.
3D X-Ray Inspection Methodology 11-1
11 - 3D X-Ray Inspection Methodology
The X3 AXI system is an automated inline X-Ray inspection system with full 3D capabilities.
The X3 AXI system can not only do a full 2D inspection of a PCB but it can also do a 3D
inspection of the PCB. The X3 can also combine 2D and 3D to optimize between speed and
capability by using 3D only where needed.
A standard 2D X-Ray machine only has one X-Ray view, the top-down view that sees through
an object from top to bottom. For the X3, other than the regular top-down view, it can “look” at
the object from 8 different side angles and then by combining them using Digital Tomosynthesis
Reconstruction algorithms, creates slices parallel to the board surface. These slices can separate
the top side from the bottom side so that each side of the double sided board can be
independently analyzed.
The height offset of the top surface of the board can be measured using a laser device and this
information is used to compensate for board warp. It is possible to setup the parameters and the
position where the laser measurements will have to be made and the range over which the
measurement will be effective.
Although the X3 AXI system is a fully automated 3D x-ray inspection system, it has significant
manual capabilities. You can simply load a board, position the part under x-rays, select the
appropriate power level, add/edit a 3D site and scroll up and down perpendicular to the surface
of the board.
11.1 Key Applications for 3D Inspection
11.1.1 Separate Top and Bottom Side Parts
Because X-ray is able to passing through the circuit board, it produces a density projection of the
field of view. The dense areas such as the solder joints appear as a dark area on the image. For
double sided boards with solder joints on both sides of the board, the dark areas from two sides
could overlap. That causes difficulty for inspecting the quality of the solder joints when they are
obscured by the solder joints from the other side. 3D X-ray imaging solves that problem by
creating slices represent different side. Solder joint from the top side would apparent in a
different slice as the solder joints from the bottom side. The separation allows inspection for
solder quality on both side of the circuit board.