00193727-02 - 第16页

2 Change Instructions Running block covers Running block covers SIPLACE HS-50 10/2005 Edition 16 2.3 Retrofit : Switch of f the placement machine on the main switch. 2 : Examine the cover for impression of lubrication no…

100%1 / 26
Running block covers SIPLACE HS-50 2 Change Instructions Running block covers
10/2005 Edition
15
2 Change Instructions Running block
covers
2.1 Necessary tools:
Angle allen key size 2.5 mm and 5 mm
or 2
ratch plug in tool with allen key link for size 2.5 mm and 5 mm
Tong with prepaired end stop
Spread tool (Item no: 00375832-01), consists of:
- Fitting pieces (Item no: 00375829-01)
- Tong with end stop external form B (Item no: 00096450-01)
Open ended spanner size 7.
2.2 Required retrofit kits:
00371133-01 URS Hardware Plattform 2 2
2 Change Instructions Running block covers Running block covers SIPLACE HS-50
10/2005 Edition
16
2.3 Retrofit
: Switch off the placement machine on the main switch.
2
: Examine the cover for impression of lubrication nozzle.
2
Abb. 2.10 - 1 Examination of cover for impression of lubrication nozzle
2
: Test the old covers with the gauge and note the result of the test in the annexed exel file (pls
send this file to: kleinwolfgang@siemens.com).
The regular value of the nozzle is about 2.75 - 2.80 mm.
2
2
2
2
2
2
2
2
2
2
2
2
Running block covers SIPLACE HS-50 2 Change Instructions Running block covers
10/2005 Edition
17
: Move gantry to end of rail.
2
The gantry must not be moved as long as the covers are disassembled. Otherwise the ball deflec-
tor may lift off with the effect of loosing balls. 2
2
: Unscrew and remove both cover screws.
2
Abb. 2.10 - 2 Remove both cover screws
2
: Remove the cover.
2
Abb. 2.10 - 3 Removal of cover
2
2
2