00191025-01 - 第110页

5 Placement S IPLACE 80S/F/G User’s Manual 5.6 Error Menus Edition 12/96 from Software Version S R.009.xx 5 - 34 5.6.5 Machine Error M enus 1 and 2 The menu "Machine e rror" is di splayed on the scr een if ther…

100%1 / 736
SIPLACE 80S/F/G User’s Manual 5 Placement
Edition 12/96 from Software Version SR.009.xx 5.6 Error Menus
5 - 33
Set location full
In this menu, locations 1-4 can be set individually to "full".
Here fixed table 1 corresponds to location 1, and fixed table 2 to location 3.
Display set-up
If a set-up exists, in this menu the set-up can be displayed for every location.
Gantry functions
Use the cursor keys to select the menu item "Gantry functions" if the track errors were caused by faults in
the gantry. Then press the return key.
The screen displays the menu described in Section 6.2 "Gantry Functions 80S".
5.6.4.3 Extended Range of Functions with the SIPLACE 80 F
WPC functions
If the track errors are being caused by the wafflepack changer, use the cursor keys to select the menu item
"WPC functions".
Next press the return key. The screen displays the menu "WPC functions" which is described in Section
6.8 "Functions: Wafflepack Changer". In this menu individual functions of the wafflepack changer can be
carried out. The wafflepack changer is described in more detail in Section 8 (components supply).
Select WPC
If more than one wafflepack changer has been configured, a single wafflepack changer can be selected
individually in this menu.
Only operation with a single wafflepack changer has at the present time been implemented.
5 Placement SIPLACE 80S/F/G User’s Manual
5.6 Error Menus Edition 12/96 from Software Version SR.009.xx
5 - 34
5.6.5 Machine Error Menus 1 and 2
The menu "Machine error" is displayed on the screen if there is a functional error at the machine (e.g. screw-
driver pick-up position is jammed) which results in it not being possible for the machine to continue with place-
ment. When the menu is quit, a head reference run without vacuum test is carried out over the rejects tray.
Fig. 5.6.4
5.6.5.1 Range of Functions: Operator
Display errors
To obtain a display of all errors which have occurred use the
cursor keys
to select the menu point "Display
errors". Then press the
Return key
. The menu "Display errors" described in Section 5.7 (Display functions)
will be displayed on the screen.
Abort placement
To quit the error menu without continuing with placement, use the cursor keys to select the menu item
"Abort placement". Next press the return key. The board which is on the conveyor is moved onwards onto
the output conveyor. The components which are at the placement head are ejected. The gantries are
moved into the waiting position.
Continue placement
To continue with placement use the cursor keys to select the menu item "Continue placement", and then
press the return key. The machine performs a head reference run and then continues with placement.
SI 80 V 9.x
Rüstung :
Display errors
Confirm errors
Machine options
Error
State
Action
:
:
:
Machine error 1
Abort placement
Display errors
Error treatment - machine error gantry 1
Continue placement
Cluster:
Continue placement
SIPLACE 80S/F/G User’s Manual 5 Placement
Edition 12/96 from Software Version SR.009.xx 5.6 Error Menus
5 - 35
5.6.5.2 Range of Functions: Line Engineer
Star head
If the machine errors are being caused by errors at the star head, use the cursor keys to select the menu
item "star head". After doing so, press the return key. The screen then displays the menu "Star head" which
is described in Section 6.3 "Star Head Functions 80S". In this menu you can check the functions of the star
head.
Cycle mode
With the aid of the cursor keys position the cursor bar over the menu item "Cycle mode". Next press the
return key. For every step of the placement sequence you must now press the start button.
Table functions
If the machine error was caused by a program loss at the components table, select the "Table functions"
menu item. Now press the return key. The menu described in Section 6.9 "Table functions" will now
appear on the screen.
Gantry functions
Use the cursor keys to select the menu item "Gantry functions" if the machine errors were caused by faults
in the gantry. Then press the return key.
The menu described in Section 6.2 "Gantry Functions 80S" will be displayed on the screen.
5.6.5.3 Extended Range of Functions for the SIPLACE 80 F
IC head
If the machine errors are being caused by errors at the IC head, use the cursor keys to select the menu
item "IC head". After doing so, press the return key. The screen will display the menu "IC head" which is
described in Section 6.6 "Head Functions 80 F". In this menu you can check the functions of the IC head.
Wafflepack changer functions
If the machine errors are being caused by the wafflepack changer, use the cursor keys to select the menu
item "WPC functions". Next press the return key. The screen then displays the menu "WPC functions"
which is described in Section 6.8 "Functions: Wafflepack Changer". In this menu individual functions of the
wafflepack changer can be performed. The wafflepack changer is described in more detail in Section 8
(Components supply).
Select WPC
If more than one wafflepack changer has been configured, a single wafflepack changer can be selected
individually in this menu.
With edition 06/96, operation is at the present time only possible with just one wafflepack changer.