00191025-01 - 第13页

SIPLACE 80S/F/G User’s Manual 0 Introduction Edition 07/97 from S oftware Version SR.010.xx 0.2 Technical Data 0 - 9 0.2 Techni cal Data 0.2.1 SIPLACE 80S 0.2. 1.1 Gantr y Axes 1 and 2 (8 0S) 0.2. 1.2 Revolver Head 80S (…

100%1 / 736
0 Introduction SIPLACE 80S/F/G User’s Manual
0.1 General Edition 07/97 from Software Version SR.010.xx
0 - 8
SIPLACE 80S/F/G User’s Manual 0 Introduction
Edition 07/97 from Software Version SR.010.xx 0.2 Technical Data
0 - 9
0.2 Technical Data
0.2.1 SIPLACE 80S
0.2.1.1 Gantry Axes 1 and 2 (80S)
0.2.1.2 Revolver Head 80S (Star Head)
Gantry axes 1 and 2
Drive D.C. servo motors
Path-measuring system Linear incremental scales
Resolution x / y axes 2.5
µ
m
Speed x axis 2.0 m/s
Speed y axis 2.5 m/s
Revolver head (Star head)
Programmable placement force (z axis) 2.4 to 4.0 N
Nozzle types 8
Components to be assembled
Max. height 6.0 mm
Min. pitch 0.5 mm
Dimensions: 0.5 mm x 1.0 mm to 14 mm x 18 mm
Weight up to 2 grams
Path dp1/dp2 turning axes
± 180
o
Resolution dp1/dp2 turning axes
0.1
o
Resolution star head axis
0.005
o
Z axis stroke 14 mm
0 Introduction SIPLACE 80S/F/G User’s Manual
0.2 Technical Data Edition 07/97 from Software Version SR.010.xx
0 - 10
0.2.1.3 CRDL Tester 80S
Note concerning the tables
The figures for accuracy are composed of two values.
-
The measurement tolerance in % of reading (rdg)
-
A basic error (abs.) which is inherent in every range of measurement
E.g. measured value 200 pF ± 3 % Tol.: (±) 6 pF + (±) 2 pF (rdg) = ± 8 pF measurement tolerance
CRDL tester
C test
Range of measurement
Accuracy
Measurement
voltage at 1.6 kHz
Comment
Tol. [%] (rdg) abs.
from 10 to 100 pF ± 3 % ± 1 pF 5 V min. 10 pF
from 100 pF to 1 nF ± 3 % ± 2 pF 5 V
from 1 nF to 10 nF ± 3 % ± 20 pF 0.5 V
from 10 nF to 100 nF ± 3 % ± 100 pF 0.5 V
from 100 nF to 1
µ
F ± 4 % ± 1 nF 0.5 V
from 1
µ
F to 10
µ
F ± 4 % ± 20 nF 0.5 V
from 10
µ
F to 100
µ
F ± 5 % ± 100 nF 0.5 V
from 100
µ
F to 220
µ
F ± 5 % ± 200 nF 0.5 V max 220 µF
Polarity measurement of the tantalum capacitors has not yet been approved.
R test
Range of measurement
Accuracy
Measurement
voltage at 1.6 kHz
Comment
Tol. [%] (rdg) abs.
10
to 100
± 3 % ± 1
0.5 V min. 10
100
to 1 k
± 3 % ± 2
0.5 V
1 k
to 10 k
± 3 % ± 50
0.5 V
10 k
to 100 k
± 3 % ± 200
0.5 V
100 k
to 1 M
± 3 % ± 500
5 V
1 M
to 10 M
± 5 % ± 20 k
5 V
10 M
to 22 M
± 10 % ± 100 k
5 V max. 22 M
In the range of measurement below 100
it will be necessary in the tolerance stated to take into account the possible
ground leakage resistance through oxidation layers on the component or deposits
on the measuring jaws. (Up to 6
has been measured during trials)