00191025-01 - 第145页
SIPLACE 80S/F/G User’s Manual 6 Single Functi ons Edition 07/97 from S oftware Version SR.010.xx 6.2 Gantry Functions 80S 6 - 13 6.2. 1.4 Gantry Reference Run With the function gantr y referenc e run the act ive gantry p…

6 Single Functions SIPLACE 80S/F/G User’s Manual
6.2 Gantry Functions 80S Edition 07/97 from Software Version SR.010.xx
6 - 12
●
Press the
Esc key
twice to quit the menu. The gantry performs a reference run and the program jumps
back to the menu "Single functions".
NOTE
All travel functions of the main axes (x, y) must be launched using the start key. On the screen you will be
requested to press the start key by the message "Press start key” following the menu item "Action:” If the
protective cover is not closed you will be asked to close it by a message on the screen.
6.2.1.1 Go to Service Position
In the service position the gantry is in a position in which it is possible to carry out work on the placement head
and also other parts of the gantry.
To go to the service position proceed as follows:
●
Use the
cursor keys
within the menu "Gantry functions" to position the cursor bar over the menu item "Go
to service pos'n".
●
Press the
Return key
.
●
Press, for as long as you are asked to do so, the
Start button
. The gantry travels to the service position.
6.2.1.2 Go to Waiting Position
The waiting position is the position in the machine which gantry travels to when the gantry is not required for
the placement sequence.
To go to the waiting position proceed as follows:
●
Use the
cursor keys
within the menu "Gantry functions" to position the cursor bar over the menu item "Go
to waiting pos'n".
●
Press the
Return key
.
●
Press, for as long as you are asked to do so, the
Start button
. The gantry travels to the waiting position.
6.2.1.3 Go to Zero Pulse
Zero pulse is the position of the gantry used as a basis for the counter sequences of the incremental
encoders.
To go to the zero pulse proceed as follows:
●
Use the
cursor keys
within the menu "Gantry functions" to position the cursor bar over the menu item "Go
to zero pulse".
●
Press the
Return key
.
●
Press, for as long as you are asked to do so, the
Start button
. The gantry travels to the zero pulse of the x
and y axes.

SIPLACE 80S/F/G User’s Manual 6 Single Functions
Edition 07/97 from Software Version SR.010.xx 6.2 Gantry Functions 80S
6 - 13
6.2.1.4 Gantry Reference Run
With the function gantry reference run the active gantry performs a reference run with the x and y axes.
To carry out the gantry reference run proceed as follows:
●
Use the
cursor keys
within the menu "Gantry functions" to position the cursor bar over the menu item "Gan-
try reference run".
●
Press the
Return key
.
●
Press, for as long as you are asked to do so, the
Start button
. The gantry performs a reference run.

6 Single Functions SIPLACE 80S/F/G User’s Manual
6.2 Gantry Functions 80S Edition 07/97 from Software Version SR.010.xx
6 - 14