00191025-01 - 第173页
SIPLACE 80S/F/G User’s Manual 6 Single Functions Edition 07/97 from S oftware Version SR.010.xx 6.6 Head Functions 80 F 6 - 41 Fig. 6.6.2 SI 80F V 10.x Rüstung : Display errors Confirm errors Machine options Vision syste…

6 Single Functions SIPLACE 80S/F/G User’s Manual
6.6 Head Functions 80 F Edition 07/97 from Software Version SR.010.xx
6 - 40
Fig. 6.6.1
6.6.1.1 Head Reference Run
Upon activation of this function the z and d axes perform a reference run.
To launch the function "Head reference run" proceed as follows:
●
In the menu "IC head" with the aid of the
cursor keys
position the cursor bar over the menu item "Head ref-
erence run".
Press the
Return key
. The z-and d axes will perform a reference run.
6.6.1.2 Vacuum Test
Upon activation of this function the vacuum and the height of nozzle which is at the head are measured. There
must be one nozzle at the head.
To implement this function proceed as follows:
●
In the menu "IC head" with the aid of the
cursor keys
position the cursor bar over the menu item
"Vacuum test."
Press the
Return key
. The vacuum value and the height of the current nozzle will be measured. The measured
value of the vacuum is displayed in the righthand window of the menu "IC head".
SI 80F V 10.x
Rüstung :
Display errors
Confirm errors
Machine options
Software options Vision system
Error
State
Action
:
:
:
Single functions
Transportfkt.
Gantry
IC head
Head reference run
Vacuum test
Clamping Z axis
Vacuum Off
Blow out Off
Turn D axis
Return nozzle
Blow out On
Pick-up nozzle
Nozzle changer set-up
Current nozzle number: 416
Single functions
Vacuum On
Single functions

SIPLACE 80S/F/G User’s Manual 6 Single Functions
Edition 07/97 from Software Version SR.010.xx 6.6 Head Functions 80 F
6 - 41
Fig. 6.6.2
SI 80F V 10.x
Rüstung :
Display errors
Confirm errors
Machine options
Vision system
Error
State
Action
:
:
:
Single functions
Breitenverstell.
Gantry
Prüfgerät
Pipettenkonf.
IC head
Current nozzle number:
Vacuum values open:
Single functions
416
25 %
Software options
Single functions
Head reference run
Turn D axis
Vacuum On
Vacuum Off
Blow out On
Blow out Off
Return nozzle
Pick-up nozzle
Nozzle changer set-up
Vacuum test

6 Single Functions SIPLACE 80S/F/G User’s Manual
6.6 Head Functions 80 F Edition 07/97 from Software Version SR.010.xx
6 - 42
6.6.1.3 Clamping z Axis
Upon activation of this function the z axis is clamped.
To launch the function "Clamping z axis" proceed as follows.
●
In the menu "IC head" with the aid of the
cursor keys
position the cursor bar over the menu item
"Clamping z axis".
Fig. 6.6.3
●
Press the
return key
. The z axis is then clamped. In the menu window the message "IC head: Z axis clamp-
ing actuated" is displayed.
●
Terminate this function with the
Esc key
. The Z axis is then unclamped.
6.6.1.4 Turn D Axis
Upon activation of this function the D axis can be checked. Here the D axis is rotated.
To launch the function "Turn D axis" proceed as follows:
●
In the menu "IC head" with the aid of the
cursor keys
position the cursor bar over the menu item
"Turn D axis".
Press the
Return key
. The D axis will be rotated.
SI 80F V 10.x
Nutzen:
Rüstung :
BE - Zuführung Display errors
Confirm errors
Machine options
Software options Vision system
Error
State
Action
:
:
:
Single functions
Portal 2
Transportfkt.
Breitenverstell.
Portal 1
Nullimpuls anfahren
Portal - Referenzlauf
Kopf
Prüfgerät
Pipettenkonf.
IC head
Head reference run
Vacuum test
Vakuum aus
Blasez-Achse ist geklemmts
d-Achse drehen
PipettESC
Blasen ein
Pipette abholen
IC head: Z axis clamping actuated
ESC.: abort
Current nozzle number: 416
Clamping Z axis
Gantry
Single functions
Single functions
Clamping Z axis