00191025-01 - 第179页
SIPLACE 80S/F/G User’s Manual 6 Single Functions Edition 07/97 from S oftware Version SR.010.xx 6.7 Transport Functions 8 0 F 6 - 47 6.7 Transport Fun ctions 80 F NOTE The trans port functio ns of the S IPLACE 80F are id…

6 Single Functions SIPLACE 80S/F/G User’s Manual
6.6 Head Functions 80 F Edition 07/97 from Software Version SR.010.xx
6 - 46
Fig. 6.6.5
The column "Programmed" contains the set-up specified by the line computer.
The column "Actual" contains the set-up actually to be found at the nozzle changer.
Set up the nozzles to the "Programmed" state and confirm with the
Return key
. All nozzles must be confirmed
individually.
NOTE
In the software up to 20 nozzle garages can be defined.
Esc: abort
Nozzle changer set-up
Function
State
Action
:
:
:
Garage
1
3
4
Actual
416
418
419
Programmed
416
418
419
Nozzle type
Current nozzle number: 418
Ret.: accept
2
417
418
<=
to change
5
6
7
8
9
10
11
416
416
416
416
416
416
416
416
416
416
416
416
416
416

SIPLACE 80S/F/G User’s Manual 6 Single Functions
Edition 07/97 from Software Version SR.010.xx 6.7 Transport Functions 80 F
6 - 47
6.7 Transport Functions 80 F
NOTE
The transport functions of the SIPLACE 80F are identical with the transport functions of the SIPLACE 80S.
Differences can only exist in the software version notice and in the header of the screen menus. This does not
however have any influence on the functions.
For this reason in this section reference is made to Section 6.4 "Transport Functions 80S" of the
SIPLACE 80S information.
If at a later point of time function changes or additions are made which affect the SIPLACE 80S Section 6.7
"Transport Functions 80 F" will be revised accordingly.

6 Single Functions SIPLACE 80S/F/G User’s Manual
6.7 Transport Functions 80 F Edition 07/97 from Software Version SR.010.xx
6 - 48