00191025-01 - 第364页

SIPLACE 80S/F/G User’s Manual 9 Maintenance Edition 07/97 from S oftware Version SR.010.xx 9.1 Overview 9 - 5 9.1.3 SIPLACE G Placement Machine Fig. 9.1.3 SIPLACE G: Modules requiri ng maintenance Key to Fig. 9.1.3 1 Adh…

100%1 / 736
9 Maintenance SIPLACE 80S/F/G User’s Manual
9.1 Overview Edition 07/97 from Software Version SR.010.xx
9 - 4
9.1.2 SIPLACE 80F Placement Machine
Fig. 9.1.2 SIPLACE 80F: Modules requiring maintenance
Key to
Fig. 9.1.2
1 Revolver head, gantry 1 10 Empty tape cutters
2 IC head 11 PCB transport
3 X axis, Gantry 1 12 Rejects container for the revolver head
4 Y axis, Gantry 1 13 Rejects container for IC head, component
5 Safety covers with guide rails vision camera, coplanarity laser module
6 Compressed air unit and nozzle changer
7 Servo unit, filter mat 14 Control unit of PCB Handling
8 Control unit, filter mat 15 Bar code strips
9 Changeable components tables 16 Wafflepack changer
SIPLACE 80S/F/G User’s Manual 9 Maintenance
Edition 07/97 from Software Version SR.010.xx 9.1 Overview
9 - 5
9.1.3 SIPLACE G Placement Machine
Fig. 9.1.3 SIPLACE G: Modules requiring maintenance
Key to
Fig. 9.1.3
1 Adhesive Application Heads 1 and 2
2 Adhesive Application Head 3
3 X axis, Gantry 1
4 Y axis, Gantry 1
5 Safety hoods with guide rails
6 Compressed air unit
7 Servo unit, filter mat
8 Control unit, filter mat
9 PCB transport
10 Control unit - PCB handling
9 Maintenance SIPLACE 80S/F/G User’s Manual
9.1 Overview Edition 07/97 from Software Version SR.010.xx
9 - 6
9.1.4 General Information (SIPLACE 80S, 80F, G)
9.1.4.1 Safety Instructions
DANGER
!
!
!
When carrying out any work you must comply with the safety instructions in this user’s manual.
The key-operated switch may be unlocked only by authorized persons and once work is completed
the key must be kept under lock.
Do not carry out any cleaning work with alcohol in the presence of naked lights or fire.
Always keep to the order of work specified.
DANGER
!
!
!
The Siplace 80F machine is equipped with the coplanarity laser module. The laser operates within a power
and wavelength range which is hazardous for the skin and eyes. For this reason special safety rules apply;
see also the section 7.10 Coplanarity Laser Module (SIPLACE 80F only).
Do not tamper in any way whatsoever with the safety devices!
Fault correction and repairs to the laser module and safety plug must be carried out by the manufacturer.
9.1.4.2 Information on the Sequence of Work
NOTE
The maintenance frequencies specified for the checking and replacing the filter elements apply only for the
specified compressed air quality, see Compressed Air Specification. Otherwise there is an increase in mainte-
nance frequencies accordingly.
Make a note in the maintenance schedule of the maintenance work which has been carried out.
We recommend you keep to the sequence of work specified in the maintenance schedule.
NOTE
If you wish to move the gantry by hand after switching off the SIPLACE 80F placement machine it is essential
that you observe the following information:
The z axis (sleeve) must be in its top end position after the machine is switched off. If this is not the case, this
indicates a fault. You should inform the SMD service department.