SIPLACE 80S/F/G User’s Manual 9 Maintenance
Edition 07/97 from Software Version SR.010.xx 9.5 Revolver Head, Segment Version 2 (New Nozzle Seat)
9 - 49
Fig. 9.5.4 Location of subassemblies in the "Housing complete with star" which are to be maintained
9.5.3.2 Installation of the Housing Complete with Star
After completing all maintenance work remove the "housing complete with star" from the mounting rack
and place the housing onto the centering pins of the "support plate complete".
Fix the housing in place (3 hexagon socket screws M4) and make sure that the screws are tight.
Reconnect all electrical plug-in connections (see Fig. 9.5.3).
Make sure the plug-in connections are not loose and that cable routing is correct. Reattach the cable lac-
ing, as shown in Fig. 9.5.2.
For the installation of the segments you will require the SIPLACE test program, as a reference run will be
necessary before installation (= reference run without segments). Continue, then, work on the SIPLACE
80S with the section 9.5.3.3 Concluding work - but only after maintenance of the two placement heads .
9 Maintenance SIPLACE 80S/F/G User’s Manual
9.5 Revolver Head, Segment Version 2 (New Nozzle Seat) Edition 07/97 from Software Version SR.010.xx
9 - 50
9.5.3.3 Concluding work
For this work you will require the SIPLACE test program !
DANGER
!
!
!
The test program may only be used by authorized persons trained at Siemens AG.
The machine setter password is necessary for the executive functions.
If the test program is used incorrectly or improperly there is an increased danger of accident and also the dan-
ger of damage to the machine.
The key-operated switch will remain locked (= not actuated) for all work described below, and the protective
covers will remain closed.
Proceed in the sequence of operations given.
Close the protective covers and lock the key-operated switch. Lock away in turn the key! Switch the
machine on.
Load the SIPLACE test program from the diskette.
First carry out the star reference run and without segments so as to position the star position 1 at star sta-
tion 1 (= below). Afterwards you can return the segments to their allocations in the star. Proceed as follows:
Check whether the z axis is in the top end position. If it is not first select: menu "Axes"
z axis
Refer-
ence point. After this select from the "axes" menu
Star axis
Reference point.
Continue work with installation of the segments, as described in the section of the same name.
First calibrate the PCB vision system and next the component vision system.
NOTE
In the course of this work first the head and next the gantry reference run is carried out.
Check or determine the machine zero point.
Load the station software and start the placement sequence.
9.5.4 Turning stations dp1 and dp2
NOTE
for this maintenance work the "housing complete with star" is removed and placed on the "mounting rack for
housing", as described in the section 9.5.3.1 Removal of the Housing Complete with Star.
The turning stations remain installed on the housing for the duration of maintenance as otherwise you will
need to reset the track signals after reinstallation!
The location of the turning stations on the "housing complete with star" is shown in Fig. 9.5.4.
SIPLACE 80S/F/G User’s Manual 9 Maintenance
Edition 07/97 from Software Version SR.010.xx 9.5 Revolver Head, Segment Version 2 (New Nozzle Seat)
9 - 51
9.5.4.1 Cleaning and Greasing the Tooth Engagement of the Swivel-In Lever
NOTE
If the tooth engagement on the swivel-in lever is not greased this can lead to stiffness when the lever swivels
in or out of position and this in turn to fatal error message Nos. 1 or 2 with placement being stopped immedi-
ately.
Clean the teeth of both the pinion and also the tooth segment on the swivel-in lever with a brush dipped in
alcohol (see Fig. 9.5.5). While doing so move the swivel-in lever by hand.
Carefully dry off the teeth if necessary with compressed air and grease the tooth segment sparingly with
Unimoly GL82.
Swivel the lever repeatedly in and out in order to distribute the grease evenly.
Fig. 9.5.5 Maintenance of turning stations 1 and 2