10 SIPL ACE G SIPLACE 80S /F/G User’s Manual 10.3 Machine Options Edition 07/97 from Software Version S R.010.xx 10 - 12

100%1 / 736
SIPLACE 80S/F/G User’s Manual 10 SIPLACE G
Edition 07/97 from Software Version SR.010.xx 10.3 Machine Options
10 - 11
10.3.5 Ink Spot Recognition
The vision system of the SIPLACE G can be used for interrogating ink spots in addition to PCB board position
recognition. The ink spot is a defined fiducial on a board or single circuit.
When necessary (defective board or single circuit) this fiducial is made undetectable. If the machine does not
recognize the ink spot, the board or single circuit in question will not be glued. Ink spots are particularly suit-
able for boards which accommodate multiple identical single circuits.
Once the
line engineer password
has been typed in under the menu "Machine options", ink spot recognition
can beactivated or deactivated.
If ink spot recognition is switched off, all boards will be glued.
10 SIPLACE G SIPLACE 80S/F/G User’s Manual
10.3 Machine Options Edition 07/97 from Software Version SR.010.xx
10 - 12
SIPLACE 80S/F/G User’s Manual 10 SIPLACE G
Edition 07/97 from Software Version SR.010.xx 10.4 Glueing Adjustments
10 - 13
10.4 Glueing Adjustments
In the menu "Glueing adjustmts" you can call up and change the glueing parameters and the data of the glue
cleaning pad.
To access the menu item "Glueing adjustmts" proceed as follows:
In the "Main menu" move the cursor bar by means of the
cursor keys
onto the menu item "Glueing adjust-
mts".
Press the
Return key
. The menu "Glueing adjustmts" is then shown on the screen.
Fig. 10.4.1
SI 80G V 10.x
Rüstung :
Machine options
Software options
Single functions
Vision system
Error
State
Action
:
:
:
Display errors
Glueing parameters
Glueing adjustments
New cluster
Glueing adjustmts
Glueing adjustmts
Glueing parameters
Cleaning pad data
Modify system data
Cluster: