SIPLACE 80S/F/G User’s Manual 11 Station Extensions Edition 07/97 from S oftware Version SR.010.xx 11.3 PCB Bar-Code 11 - 17 11.3.5 Technical Data Resolu tion Finest li ne thicknes s 0.19 to 0.3 mm Reading s peed 600 sca…

100%1 / 736
11 Station Extensions SIPLACE 80S/F/G User’s Manual
11.3 PCB Bar-Code Edition 07/97 from Software Version SR.010.xx
11 - 16
11.3.4.1 Adjusting the Reading Beam
Place the board onto the input board.
The SR_CONF_LPBC.100.001 diskette must still be loaded and the control system be switched on.
Adjust the reading head so that the laser beam can scan the entire bar code when the board is moved by.
At this point note the reading orientation of the bar code.
Switch the read beam ON using the + key on the keyboard.
Move the board over the bar-code reader. The bar code which has been read will be displayed on the
screen.
Switch the read beam OFF using the -key on the keyboard.
NOTE
For further details on operating and programming, please refer to the UNIX line computer user's manual.
Please note,
the smaller the reading angle the larger the effective reading length, and the larger this effective line length
is, the more certain reading of the bar code will be.
Fig. 11.3.2 Reading the bar-code
SIPLACE 80S/F/G User’s Manual 11 Station Extensions
Edition 07/97 from Software Version SR.010.xx 11.3 PCB Bar-Code
11 - 17
11.3.5 Technical Data
Resolution Finest line thickness 0.19 to 0.3 mm
Reading speed 600 scans/sec.
Reading distance 60 to 90 mm
Reading window 90 mm (max. bar-code length permitted)
Angle of reading head to the bar code 5 to 10°
Light source
Laser diode, 670 nm
1 mW
Laser class 2
Type of protection IP 65
Readable bar-code types
Code 39
Code 128 / EAN 128
Code 2/5 interleaved
Codabar
2/5 IATA
2/5 INDUSTRIAL
UPC
EAN
Pharma code
EAN Addendum
(others available on request)
Line length
4 mm
Requirement: with a board speed of 300 mm/sec
and a scan rate of 600 scans/sec it must be possi-
ble to make 3 readings
Contrast ratio as per DIN 66236
70%
Permitted color of lines
black
dark green
dark blue
Permitted background colors
white
beige
yellow
orange
Bar-code length
(including the two end areas)
90 mm
11 Station Extensions SIPLACE 80S/F/G User’s Manual
11.3 PCB Bar-Code Edition 07/97 from Software Version SR.010.xx