19 Error Messages S IPLACE 80S/F/G User’s Manual 19.1 Error Mess ages Edition 12/96 from Software Vers ion SR.009.xx 19 - 6 30 BERO SZ2 not released (close segment) CAUSE ● Proximi ty switch de fective; component ja mmed…

100%1 / 736
SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 5
23 End position BERO of centering station not being activated
CAUSE
Bero defective; mechanism of the centering station stiff; recuperator spring worn out.
REMEDY
Fit new Bero; maintain centering station; call SMD Service.
25 Error in programming of the CRDL
CAUSE
CRDL tester configured in software, but tester itself not present; communication interrupted at the
CRDL tester; interrupt wiring of MC CRDL tester defective.
REMEDY
Set corresponding parameters (CRDL tester) to non-active.
26 Measurement trigger BERO of centering station is not released
CAUSE
Bero defective; mechanism of the centering station stiff; actuating plate bent; motor control board
defective.
REMEDY
Fit new Bero; maintain centering station; call SMD Service.
27 Component cannot be rejected
CAUSE
Positive airflow valve not switching, cable break at the valve
REMEDY
Check and repair wiring
28 The nozzle in the reject position is clogged
CAUSE
Nozzle worn, air duct of the segment blocked
REMEDY
Fit new nozzle, clean or replace segment
29 BERO SZ2 not released (open segment)
CAUSE
Proximity switch defective; component jammed between screwdriver and segment;
motor of the screwdriver defective.
REMEDY
Replace proximity switch, adjust sensing distance; remove component; check toothing for damage;
replace motor with hub, carry out calibration on the motor control board.
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 6
30 BERO SZ2 not released (close segment)
CAUSE
Proximity switch defective; component jammed between screwdriver and segment;
motor of the screwdriver defective.
REMEDY
Replace proximity switch, adjust sensing distance; remove component; check toothing for damage;
replace motor with hub, carry out calibration on the motor control board.
38 Star axis does not reach setpoint position ?
CAUSE
Segment slit position incorrect at insertion; component jammed between toothed belt and toothed
belt pulley; speed was input incorrectly in the MA_DATA; power supply interrupted; motor defective;
belt tension not correct; segment cam is rubbing against the Z axis.
REMEDY
Insert segment with correct slit position; remove component; correct speed value correspondingly;
check plugged connections; replace motor, adjust toothed belt tension, carry out calibration of the
servo board; slacken cam leaf springs of segment and realign cam.
43 Component not at nozzle after pick-up
CAUSE
Suction face of the nozzle damaged; nozzle too small; component was not supplied.
REMEDY
Fit new nozzle; check component feed.
44 Component not at nozzle before placement
CAUSE
Suction face of the nozzle damaged; nozzle too small; jaws of the centering station bouncing; com-
ponent was not picked up properly; vacuum in the holding circuit too low; vacuum board defective.
REMEDY
Fit new nozzle; carry out calibration of the motor control board; check component feed, call SMD
Service.
48 Results of vac measurement of pick-up & reject station inversed
CAUSE
Vacuum circuit defective; compressed air bad.
REMEDY
Check vacuum circuit; check compressed air.
50 SZ1 only succeeded on the second attempt
CAUSE
Stiffness in the gearwheel/pinion of the screwdriver; stiffness in the pusher movement; calibration of
the motor control board not optimal.
REMEDY
Maintain screwdriver; maintain segment; carry out calibration of the motor control board.
SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 7
52 BERO SZ2 not being actuated
CAUSE
Bad plugged connection of the screwdriver at the gantry board; motor control board
defective.
REMEDY
Check plugged connections; fit new motor control board, carry out calibration of the axes.
53 SZ2 only succeeded on second attempt
CAUSE
Stiffness in the gearwheel/pinion of the screwdriver; stiffness in the pusher movement; calibration of
the motor control board not optimal.
REMEDY
Maintain screwdriver; maintain segment; carry out calibration of the motor control board.
54 BERO SZ1 not being actuated
CAUSE
Bad plugged connection of the screwdriver at the gantry board; motor control board defective.
REMEDY
Check plugged connections; fit new motor control board, carry out calibration of the axes.
59 X axis does not reach setpoint position
CAUSE
Mechanism jamming; toothed belt parted; drive motor with tacho defective; calibration of the axis
incorrect.
REMEDY
Check mechanism; fit new toothed belt; fit new motor with tacho; carry out axis calibration.
60 Y axis does not reach setpoint position
CAUSE
Mechanism jamming; toothed belt parted; drive motor with tacho defective; calibration of the axis
incorrect.
REMEDY
Check mechanism; fit new toothed belt; fit new motor with tacho; carry out axis calibration.
61 Z axis does not reach setpoint position
CAUSE
Cam disk in incorrect position at zero pulse; motor defective; z axis jamming.
REMEDY
Fit cam disk in correct rotational position; redetermine zero point correction; replace motor; carry out
axis calibration; fit spare placement head.