19 Error Messages S IPLACE 80S/F/G User’s Manual 19.1 Error Mess ages Edition 12/96 from Software Vers ion SR.009.xx 19 - 12 132 Foil torn CAUSE ● The cove r foil is t orn; the foil removal fo rce has been s et incorrect…

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 11
125 Coplanarity: clamping of z axis does not work
CAUSE
●
Clamping reacts too slow; clamping is defective.
REMEDY
●
Operate clamping repeatedly; check clamping.
126 Unknown telegram to table
CAUSE
●
Obsolete
TISCH.HEX
file.
REMEDY
●
Update
TISCH.HEX
file.
127 Caution: Filling level of rej. comp. receptacle 70%
CAUSE
●
Does not occur
REMEDY
●
128 Receptacle of rejected componentes full
CAUSE
●
Does not occur
REMEDY
●
129 Communication table-feeder interrupted
CAUSE
●
Since the last booting, the connection with the conveyor has been interrupted; the conveyor is not
plugged in; cable is defective.
REMEDY
●
Plug in the conveyor; check the cable.
130 Communication table-feeder disturbed
CAUSE
●
Communication between table and conveyor is interrupted from time to time; the cable is defective;
the conveyor has been unplugged.
REMEDY
●
Plug in the conveyor; check the cable and plug.
131 Software-Operation in feeder disturbed
CAUSE
●
Software error
REMEDY
●
Notify AUT 5 BSM 14 - Development.

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 12
132 Foil torn
CAUSE
●
The cover foil is torn; the foil removal force has been set incorrectly; the conveyor is defective.
REMEDY
●
Repair the foil; adjust removal springs; replace the conveyor.
133 Foil not removed
CAUSE
●
The cover foil is not being stripped off; the foil removal force has been set incorrectly; the conveyor is
defective.
REMEDY
●
Pull off the foil by hand; set removal spring
134 Transport in feeder disturbed
CAUSE
●
Tape backing up; the conveyor is defective
REMEDY
●
Remove tape back-up; replace the conveyor
135 Caution: Belt end
CAUSE
●
Does not occur
REMEDY
●
136 Nozzle type not available in changer magazine SP
CAUSE
●
Not used
REMEDY
●
137 Not enough garages in changer magazine for nozzle return. SP
CAUSE
●
Nozzles should be returned
⇒
With optical garage check: all garages were checked with the board camera and are occupied.
Without optical garage check: there are not enough empty garages available for the nozzles to be
returned.
REMEDY
●
Takes place automatically: all nozzles which could not be returned are rejected.

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 13
138 Insuff. number of nozzles in changer magazine SP to pick up
CAUSE
●
Nozzles are to be picked up
⇒
With optical garage check: All garages have been checked with the board camera and are empty
Without optical garage check: One or more garages of the required nozzle type is empty.
REMEDY
●
The corresponding magazines must be set full via the menu.
139 No cluster available for nozzle pick-up SP
CAUSE
●
No cluster has been specified as specified selection.
REMEDY
●
Specifiy placement program in the line computer.
140 Nozzle-changer SP head cannot be unlocked
CAUSE
●
Key plate for locking the nozzle-changer magazine cannot be unlocked.
The plate is jamming mechanically, due to components etc.
Incorrect compressed air setting for the actuating cylinder; lacking air pressure;
the cylinder or valve is defective.
REMEDY
●
Correction of the above causes
141 Nozzle-changer SP head cannot be locked
CAUSE
●
Key plate for locking the nozzle-changer magazine cannot be unlocked.
The plate is jamming mechanically, due to components etc.
Incorrect compressed air setting for the actuating cylinder; lacking air pressure;
the cylinder or valve is defective.
REMEDY
●
Correction of the above causes
142 Communication with vision system during nozzle check faulty
CAUSE
●
Communication with the vision system is faulty.
REMEDY
●
Switch the system on and off (reset); notify SMD Service Department.
143 Desired Z-axis position exceeded during nozzle SP pick-up
CAUSE
●
The position of the x and y axes in the machine data is not correct;
the desired position of the z axis is not correct; there is no nozzle in the garage.
REMEDY
●
Correction of the above causes