00191025-01 - 第600页

SIPLACE 80S/F/G User’s Manual 19 Error Message s Edition 12/96 from S oftware Version SR.009.xx 19.1 Error Messages 19 - 13 138 Insuff. number of nozzle s in changer magazine SP to pick up CAUSE ● Nozzle s are to be pick…

100%1 / 736
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 12
132 Foil torn
CAUSE
The cover foil is torn; the foil removal force has been set incorrectly; the conveyor is defective.
REMEDY
Repair the foil; adjust removal springs; replace the conveyor.
133 Foil not removed
CAUSE
The cover foil is not being stripped off; the foil removal force has been set incorrectly; the conveyor is
defective.
REMEDY
Pull off the foil by hand; set removal spring
134 Transport in feeder disturbed
CAUSE
Tape backing up; the conveyor is defective
REMEDY
Remove tape back-up; replace the conveyor
135 Caution: Belt end
CAUSE
Does not occur
REMEDY
136 Nozzle type not available in changer magazine SP
CAUSE
Not used
REMEDY
137 Not enough garages in changer magazine for nozzle return. SP
CAUSE
Nozzles should be returned
With optical garage check: all garages were checked with the board camera and are occupied.
Without optical garage check: there are not enough empty garages available for the nozzles to be
returned.
REMEDY
Takes place automatically: all nozzles which could not be returned are rejected.
SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 13
138 Insuff. number of nozzles in changer magazine SP to pick up
CAUSE
Nozzles are to be picked up
With optical garage check: All garages have been checked with the board camera and are empty
Without optical garage check: One or more garages of the required nozzle type is empty.
REMEDY
The corresponding magazines must be set full via the menu.
139 No cluster available for nozzle pick-up SP
CAUSE
No cluster has been specified as specified selection.
REMEDY
Specifiy placement program in the line computer.
140 Nozzle-changer SP head cannot be unlocked
CAUSE
Key plate for locking the nozzle-changer magazine cannot be unlocked.
The plate is jamming mechanically, due to components etc.
Incorrect compressed air setting for the actuating cylinder; lacking air pressure;
the cylinder or valve is defective.
REMEDY
Correction of the above causes
141 Nozzle-changer SP head cannot be locked
CAUSE
Key plate for locking the nozzle-changer magazine cannot be unlocked.
The plate is jamming mechanically, due to components etc.
Incorrect compressed air setting for the actuating cylinder; lacking air pressure;
the cylinder or valve is defective.
REMEDY
Correction of the above causes
142 Communication with vision system during nozzle check faulty
CAUSE
Communication with the vision system is faulty.
REMEDY
Switch the system on and off (reset); notify SMD Service Department.
143 Desired Z-axis position exceeded during nozzle SP pick-up
CAUSE
The position of the x and y axes in the machine data is not correct;
the desired position of the z axis is not correct; there is no nozzle in the garage.
REMEDY
Correction of the above causes
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 14
144 Desired z axis position not reached during nozzle SP pick-up
CAUSE
The position of the x and y axes in the machine data is not correct (sleeve is not positioned over the
garage);
desired position of the z axis is not correct; there is already a nozzle at the sleeve.
REMEDY
Correction of the above causes
145 Desired z axis position exceeded during nozzle SP return
CAUSE
The position of the x and y axes in the machine data is not correct;
desired position of the z axis is not correct; there is no nozzle at the sleeve.
REMEDY
Correction of the above causes
146 Desired Z-axis position not reached during nozzle SP return
CAUSE
The position of the x and y axes in the machine data is not correct (sleeve is not positioned over the
garage);
desired position of the z axis is not correct; there is already a nozzle in the garage.
REMEDY
Correction of the above cause
147 Desired Z-axis position exceeded during nozzle SP rejection
CAUSE
The position of the x and y axes in the machine data is not correct ;
desired position of the z axis is not correct; there is no nozzle at the sleeve.
REMEDY
Correction of the above causes
148 Desired Z-axis position not reached during nozzle SP rejection
CAUSE
The position of the x and y axes in the machine data is not correct (sleeve not above garage);
desired position of the z axis is not correct; there is already a nozzle in the garage.
REMEDY
Correction of the above causes