00191025-01 - 第600页
SIPLACE 80S/F/G User’s Manual 19 Error Message s Edition 12/96 from S oftware Version SR.009.xx 19.1 Error Messages 19 - 13 138 Insuff. number of nozzle s in changer magazine SP to pick up CAUSE ● Nozzle s are to be pick…

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 12
132 Foil torn
CAUSE
●
The cover foil is torn; the foil removal force has been set incorrectly; the conveyor is defective.
REMEDY
●
Repair the foil; adjust removal springs; replace the conveyor.
133 Foil not removed
CAUSE
●
The cover foil is not being stripped off; the foil removal force has been set incorrectly; the conveyor is
defective.
REMEDY
●
Pull off the foil by hand; set removal spring
134 Transport in feeder disturbed
CAUSE
●
Tape backing up; the conveyor is defective
REMEDY
●
Remove tape back-up; replace the conveyor
135 Caution: Belt end
CAUSE
●
Does not occur
REMEDY
●
136 Nozzle type not available in changer magazine SP
CAUSE
●
Not used
REMEDY
●
137 Not enough garages in changer magazine for nozzle return. SP
CAUSE
●
Nozzles should be returned
⇒
With optical garage check: all garages were checked with the board camera and are occupied.
Without optical garage check: there are not enough empty garages available for the nozzles to be
returned.
REMEDY
●
Takes place automatically: all nozzles which could not be returned are rejected.

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 13
138 Insuff. number of nozzles in changer magazine SP to pick up
CAUSE
●
Nozzles are to be picked up
⇒
With optical garage check: All garages have been checked with the board camera and are empty
Without optical garage check: One or more garages of the required nozzle type is empty.
REMEDY
●
The corresponding magazines must be set full via the menu.
139 No cluster available for nozzle pick-up SP
CAUSE
●
No cluster has been specified as specified selection.
REMEDY
●
Specifiy placement program in the line computer.
140 Nozzle-changer SP head cannot be unlocked
CAUSE
●
Key plate for locking the nozzle-changer magazine cannot be unlocked.
The plate is jamming mechanically, due to components etc.
Incorrect compressed air setting for the actuating cylinder; lacking air pressure;
the cylinder or valve is defective.
REMEDY
●
Correction of the above causes
141 Nozzle-changer SP head cannot be locked
CAUSE
●
Key plate for locking the nozzle-changer magazine cannot be unlocked.
The plate is jamming mechanically, due to components etc.
Incorrect compressed air setting for the actuating cylinder; lacking air pressure;
the cylinder or valve is defective.
REMEDY
●
Correction of the above causes
142 Communication with vision system during nozzle check faulty
CAUSE
●
Communication with the vision system is faulty.
REMEDY
●
Switch the system on and off (reset); notify SMD Service Department.
143 Desired Z-axis position exceeded during nozzle SP pick-up
CAUSE
●
The position of the x and y axes in the machine data is not correct;
the desired position of the z axis is not correct; there is no nozzle in the garage.
REMEDY
●
Correction of the above causes

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 14
144 Desired z axis position not reached during nozzle SP pick-up
CAUSE
●
The position of the x and y axes in the machine data is not correct (sleeve is not positioned over the
garage);
desired position of the z axis is not correct; there is already a nozzle at the sleeve.
REMEDY
●
Correction of the above causes
145 Desired z axis position exceeded during nozzle SP return
CAUSE
●
The position of the x and y axes in the machine data is not correct;
desired position of the z axis is not correct; there is no nozzle at the sleeve.
REMEDY
●
Correction of the above causes
146 Desired Z-axis position not reached during nozzle SP return
CAUSE
●
The position of the x and y axes in the machine data is not correct (sleeve is not positioned over the
garage);
desired position of the z axis is not correct; there is already a nozzle in the garage.
REMEDY
●
Correction of the above cause
147 Desired Z-axis position exceeded during nozzle SP rejection
CAUSE
●
The position of the x and y axes in the machine data is not correct ;
desired position of the z axis is not correct; there is no nozzle at the sleeve.
REMEDY
●
Correction of the above causes
148 Desired Z-axis position not reached during nozzle SP rejection
CAUSE
●
The position of the x and y axes in the machine data is not correct (sleeve not above garage);
desired position of the z axis is not correct; there is already a nozzle in the garage.
REMEDY
●
Correction of the above causes