SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 19
207 Fault in placement stat. during vac. meas.
CAUSE
Suction face of the nozzle damaged; nozzle too small; jaws of the centering station bouncing; com-
ponent was not picked up properly; vacuum in the holding circuit too low; vacuum board defective.
REMEDY
Fit new nozzle; calibration of the motor control board; check component feed, call SMD Service.
208 End position BERO of centering station not being actuated
CAUSE
End position Bero defective or incorrectly set; recuperator spring of the centering station worn out.
REMEDY
Fit new Bero, adjust; maintain centering station.
209 Counting error X axis
CAUSE
Scales dirty (incremental encoder).
REMEDY
Clean scales (incremental encoder).
210 Measurement trigger BERO of centering station not actuated
CAUSE
Distance between Bero and actuator flag too great; Bero defective
REMEDY
Correct distance to actuator flag; fit new Bero.
211 Counting error Y axis
CAUSE
Scales dirty (incremental encoder).
REMEDY
Clean scales (incremental encoder).
212 Fault during vacuum measuring in reject position
CAUSE
O-ring on the sealing piston damaged.
REMEDY
Fit new O-ring to the sealing piston.
213 Timeout during reception from coplanarity
CAUSE
Coplanarity module not plugged in
REMEDY
Plug in module
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 20
214 Check sum error of answer from coplanarity
CAUSE
Error in the response from coplanarity.
REMEDY
Check the supply voltage of the coplanarity module check; repeat measurement.
215 Position control of S axis does not work
CAUSE
The position control of the axis is not working correctly.
REMEDY
Switch off the machine (reset); check axis for stiffness.
216 Position control of X axis does not work
CAUSE
The position control of the axis is not working correctly.
REMEDY
Switch off the machine (reset); check axis for stiffness.
217 Position control of Y axis does not work
CAUSE
The position control of the axis is not working correctly.
REMEDY
Switch off the machine (reset); check axis for stiffness.
218 Answer from coplanarity has no STX
CAUSE
The first character of the answer from coplanarity is lost.
REMEDY
Check supply voltage; check jumper of the coplanarity module; repeat measurement.
219 Coplan.: Communication buffer overflow on MC
CAUSE
Too many measurement data for one component
REMEDY
Inform AUT 5 V Service or Development AUT 5 BSM 14.
220 Coplanarity cannot execute command
CAUSE
Wrong command was sent to the coplanarity module; coplanarity was not initialized
error during execution; package form data erroneous.
REMEDY
Switch machine off and back on; respecify set-up; check package form data.
SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 21
221 Programmed position of X axis outside travel range
CAUSE
Error in the local machine data (location fiducials).
REMEDY
Check the fiducial data in the machine data.
222 Programmed position of Y axis outside travel range
CAUSE
Error in the local machine data (location fiducials).
REMEDY
Check the fiducial data in the machine data.
223 Programmed position of D1 axis outside travel range
CAUSE
Programming error, should not occur.
REMEDY
224 Programmed position of D2 axis outside travel range
CAUSE
Programming error, should not occur.
REMEDY
225 Programmed position of S axis outside travel range
CAUSE
Programming error, should not occur.
REMEDY
226 Vacuum of pick-up circuit not within range
CAUSE
Segments dirty; vacuum not working properly; limits specified too low; vacuum circuit defective.
REMEDY
Maintain segments; check vacuum; extend limits; check vacuum circuit.
227 Vacuum of reject circuit not within range
CAUSE
Segments dirty; vacuum not working properly; limits specified too low; vacuum circuit defective.
REMEDY
Maintain segments; check vacuum; extend limits; check vacuum circuit.