SIPLACE 80S/F/G User’s Manual 19 Error Message s Edition 12/96 from S oftware Version SR.009.xx 19.1 Error Messages 19 - 21 221 Programmed position of X axis outside travel range CAUSE ● Error in t he local machine data …

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 20
214 Check sum error of answer from coplanarity
CAUSE
●
Error in the response from coplanarity.
REMEDY
●
Check the supply voltage of the coplanarity module check; repeat measurement.
215 Position control of S axis does not work
CAUSE
●
The position control of the axis is not working correctly.
REMEDY
●
Switch off the machine (reset); check axis for stiffness.
216 Position control of X axis does not work
CAUSE
●
The position control of the axis is not working correctly.
REMEDY
●
Switch off the machine (reset); check axis for stiffness.
217 Position control of Y axis does not work
CAUSE
●
The position control of the axis is not working correctly.
REMEDY
●
Switch off the machine (reset); check axis for stiffness.
218 Answer from coplanarity has no STX
CAUSE
●
The first character of the answer from coplanarity is lost.
REMEDY
●
Check supply voltage; check jumper of the coplanarity module; repeat measurement.
219 Coplan.: Communication buffer overflow on MC
CAUSE
●
Too many measurement data for one component
REMEDY
●
Inform AUT 5 V Service or Development AUT 5 BSM 14.
220 Coplanarity cannot execute command
CAUSE
●
Wrong command was sent to the coplanarity module; coplanarity was not initialized
error during execution; package form data erroneous.
REMEDY
●
Switch machine off and back on; respecify set-up; check package form data.

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 21
221 Programmed position of X axis outside travel range
CAUSE
●
Error in the local machine data (location fiducials).
REMEDY
●
Check the fiducial data in the machine data.
222 Programmed position of Y axis outside travel range
CAUSE
●
Error in the local machine data (location fiducials).
REMEDY
●
Check the fiducial data in the machine data.
223 Programmed position of D1 axis outside travel range
CAUSE
●
Programming error, should not occur.
REMEDY
●
224 Programmed position of D2 axis outside travel range
CAUSE
●
Programming error, should not occur.
REMEDY
●
225 Programmed position of S axis outside travel range
CAUSE
●
Programming error, should not occur.
REMEDY
●
226 Vacuum of pick-up circuit not within range
CAUSE
●
Segments dirty; vacuum not working properly; limits specified too low; vacuum circuit defective.
REMEDY
●
Maintain segments; check vacuum; extend limits; check vacuum circuit.
227 Vacuum of reject circuit not within range
CAUSE
●
Segments dirty; vacuum not working properly; limits specified too low; vacuum circuit defective.
REMEDY
●
Maintain segments; check vacuum; extend limits; check vacuum circuit.

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 22
228 Interface signals to the preceding station incorrect
CAUSE
●
Interface line not connected; cable defective; interface boards defective.
REMEDY
●
Check signal path, replace defective assemblies.
229 The input conveyor light barrier is not covered
CAUSE
●
PCB board was removed while program was executing; PCB board jamming; sensor defective.
REMEDY
●
Correct the jamming; fit new sensor.
230 The input conveyor light barrier is not released
CAUSE
●
PCB board jamming; sensor defective.
REMEDY
●
Correct the jamming; fit new sensor.
231 No PCB on the input conveyor
CAUSE
●
The PCB board was removed while being transported onto the central conveyor; sensor defective.
REMEDY
●
Under the menu "Transportation error" continue placement, place board on input conveyor; fit new
sensor.
232 The lifting table cannot be moved downwards
CAUSE
●
Beros defective; cutout triggered.
REMEDY
●
fit new Beros; close lifting table cutout.
233 Command to coplanarity is not complete
CAUSE
●
Package form data, set-up erroneous.
REMEDY
●
Re-assign set-up, repeat measurement.
234 The lifting table cannot be moved upwards
CAUSE
●
Beros defective; cutout triggered.
REMEDY
●
Fit new Beros; close lifting table cutout.