221 Programmed position of X axis outside travel range
CAUSE
Error in the local machine data (location fiducials).
REMEDY
Check the fiducial data in the machine data.
222 Programmed position of Y axis outside travel range
CAUSE
Error in the local machine data (location fiducials).
REMEDY
Check the fiducial data in the machine data.
223 Programmed position of D1 axis outside travel range
CAUSE
Programming error, should not occur.
REMEDY
224 Programmed position of D2 axis outside travel range
CAUSE
Programming error, should not occur.
REMEDY
225 Programmed position of S axis outside travel range
CAUSE
Programming error, should not occur.
REMEDY
226 Vacuum of pick-up circuit not within range
CAUSE
Segments dirty; vacuum not working properly; limits specified too low; vacuum circuit defective.
REMEDY
Maintain segments; check vacuum; extend limits; check vacuum circuit.
227 Vacuum of reject circuit not within range
CAUSE
Segments dirty; vacuum not working properly; limits specified too low; vacuum circuit defective.
REMEDY
Maintain segments; check vacuum; extend limits; check vacuum circuit.
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 22
228 Interface signals to the preceding station incorrect
CAUSE
Interface line not connected; cable defective; interface boards defective.
REMEDY
Check signal path, replace defective assemblies.
229 The input conveyor light barrier is not covered
CAUSE
PCB board was removed while program was executing; PCB board jamming; sensor defective.
REMEDY
Correct the jamming; fit new sensor.
230 The input conveyor light barrier is not released
CAUSE
PCB board jamming; sensor defective.
REMEDY
Correct the jamming; fit new sensor.
231 No PCB on the input conveyor
CAUSE
The PCB board was removed while being transported onto the central conveyor; sensor defective.
REMEDY
Under the menu "Transportation error" continue placement, place board on input conveyor; fit new
sensor.
232 The lifting table cannot be moved downwards
CAUSE
Beros defective; cutout triggered.
REMEDY
fit new Beros; close lifting table cutout.
233 Command to coplanarity is not complete
CAUSE
Package form data, set-up erroneous.
REMEDY
Re-assign set-up, repeat measurement.
234 The lifting table cannot be moved upwards
CAUSE
Beros defective; cutout triggered.
REMEDY
Fit new Beros; close lifting table cutout.
SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 23
235 Center conveyor light barrier is not released
CAUSE
PCB board jamming in the central conveyor; sensor defective.
REMEDY
Correct the jamming; fit new sensor.
236 PCB does not reach the center conveyor
CAUSE
PCB board jamming in the center conveyor; sensor defective.
REMEDY
Correct the jamming; fit new sensor.
237 Stopper jam during extension
CAUSE
Compressed air lacking; back pressure too high; stopper defective.
REMEDY
Check compressed air; adjust back pressure; replace stopper.
238 Stopper jam during retraction
CAUSE
Compressed air lacking; back pressure too high; stopper defective.
REMEDY
Check compressed air; adjust back pressure; replace stopper.
239 Component description of coplanarity is not complete
CAUSE
Package form data erroneous.
REMEDY
Check package form data and respecify set-up.
240 Command data format to coplanarity is invalid
CAUSE
Package form data, set-up, cluster erroneous.
REMEDY
Check and respecify package form data, set-up, cluster.
241 Coplanarity tolerance is zero
CAUSE
Coplanarity tolerance (max. component height tolerance) in the set-up for the placement positions of
the circuit image is zero.
REMEDY
Increase coplanarity tolerance (max. component height tolerance) and respecify set-up and cluster.