00191025-01 - 第610页
SIPLACE 80S/F/G User’s Manual 19 Error Message s Edition 12/96 from S oftware Version SR.009.xx 19.1 Error Messages 19 - 23 235 Center conveyor light barrier is not released CAUSE ● PCB board jammi ng in the c entral con…

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 22
228 Interface signals to the preceding station incorrect
CAUSE
●
Interface line not connected; cable defective; interface boards defective.
REMEDY
●
Check signal path, replace defective assemblies.
229 The input conveyor light barrier is not covered
CAUSE
●
PCB board was removed while program was executing; PCB board jamming; sensor defective.
REMEDY
●
Correct the jamming; fit new sensor.
230 The input conveyor light barrier is not released
CAUSE
●
PCB board jamming; sensor defective.
REMEDY
●
Correct the jamming; fit new sensor.
231 No PCB on the input conveyor
CAUSE
●
The PCB board was removed while being transported onto the central conveyor; sensor defective.
REMEDY
●
Under the menu "Transportation error" continue placement, place board on input conveyor; fit new
sensor.
232 The lifting table cannot be moved downwards
CAUSE
●
Beros defective; cutout triggered.
REMEDY
●
fit new Beros; close lifting table cutout.
233 Command to coplanarity is not complete
CAUSE
●
Package form data, set-up erroneous.
REMEDY
●
Re-assign set-up, repeat measurement.
234 The lifting table cannot be moved upwards
CAUSE
●
Beros defective; cutout triggered.
REMEDY
●
Fit new Beros; close lifting table cutout.

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 23
235 Center conveyor light barrier is not released
CAUSE
●
PCB board jamming in the central conveyor; sensor defective.
REMEDY
●
Correct the jamming; fit new sensor.
236 PCB does not reach the center conveyor
CAUSE
●
PCB board jamming in the center conveyor; sensor defective.
REMEDY
●
Correct the jamming; fit new sensor.
237 Stopper jam during extension
CAUSE
●
Compressed air lacking; back pressure too high; stopper defective.
REMEDY
●
Check compressed air; adjust back pressure; replace stopper.
238 Stopper jam during retraction
CAUSE
●
Compressed air lacking; back pressure too high; stopper defective.
REMEDY
●
Check compressed air; adjust back pressure; replace stopper.
239 Component description of coplanarity is not complete
CAUSE
●
Package form data erroneous.
REMEDY
●
Check package form data and respecify set-up.
240 Command data format to coplanarity is invalid
CAUSE
●
Package form data, set-up, cluster erroneous.
REMEDY
●
Check and respecify package form data, set-up, cluster.
241 Coplanarity tolerance is zero
CAUSE
●
Coplanarity tolerance (max. component height tolerance) in the set-up for the placement positions of
the circuit image is zero.
REMEDY
●
Increase coplanarity tolerance (max. component height tolerance) and respecify set-up and cluster.

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 24
242 No PCB on the center conveyor
CAUSE
●
Transportation onto output conveyor was started under single functions although there is no board
on the center conveyor; sensor in the center conveyor defective.
REMEDY
●
Only start transportation onto the output conveyor under single functions when there is a board on
the center conveyor; fit new sensor.
243 PCB does not reach the output conveyor
CAUSE
●
PCB board jamming in the center conveyor; sensor defective.
REMEDY
●
Correct the jamming; fit new sensor.
244 Center conveyor occupied
CAUSE
●
When the function "Board to center conveyor" started there already was a PCB board on the center
conveyor; sensor defective.
When the belt speed was set the center conveyor was occupied.
REMEDY
●
Remove the PCB board; fit new sensor.
245 Output conveyor occupied
CAUSE
●
When the function "Board to output conveyor" started there already was a PCB board on the output
conveyor; sensor of output conveyor defective.
When the belt speed was set output conveyor was occupied.
REMEDY
●
Remove the PCB board; fit new sensor.
246 BERO of left table side is not activated
CAUSE
●
Bero is not covered.
REMEDY
●
Check Bero.
247 Error in axis programming (left table side)
CAUSE
●
Bero of the left table side defective; axis could not be moved.
REMEDY
●
Check Bero; reboot.