19 Error Messages S IPLACE 80S/F/G User’s Manual 19.1 Error Mess ages Edition 12/96 from Software Vers ion SR.009.xx 19 - 24 242 No PCB on the center conveyor CAUSE ● Transpo rtation on to output conv eyor was s tarted u…

100%1 / 736
SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 23
235 Center conveyor light barrier is not released
CAUSE
PCB board jamming in the central conveyor; sensor defective.
REMEDY
Correct the jamming; fit new sensor.
236 PCB does not reach the center conveyor
CAUSE
PCB board jamming in the center conveyor; sensor defective.
REMEDY
Correct the jamming; fit new sensor.
237 Stopper jam during extension
CAUSE
Compressed air lacking; back pressure too high; stopper defective.
REMEDY
Check compressed air; adjust back pressure; replace stopper.
238 Stopper jam during retraction
CAUSE
Compressed air lacking; back pressure too high; stopper defective.
REMEDY
Check compressed air; adjust back pressure; replace stopper.
239 Component description of coplanarity is not complete
CAUSE
Package form data erroneous.
REMEDY
Check package form data and respecify set-up.
240 Command data format to coplanarity is invalid
CAUSE
Package form data, set-up, cluster erroneous.
REMEDY
Check and respecify package form data, set-up, cluster.
241 Coplanarity tolerance is zero
CAUSE
Coplanarity tolerance (max. component height tolerance) in the set-up for the placement positions of
the circuit image is zero.
REMEDY
Increase coplanarity tolerance (max. component height tolerance) and respecify set-up and cluster.
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 24
242 No PCB on the center conveyor
CAUSE
Transportation onto output conveyor was started under single functions although there is no board
on the center conveyor; sensor in the center conveyor defective.
REMEDY
Only start transportation onto the output conveyor under single functions when there is a board on
the center conveyor; fit new sensor.
243 PCB does not reach the output conveyor
CAUSE
PCB board jamming in the center conveyor; sensor defective.
REMEDY
Correct the jamming; fit new sensor.
244 Center conveyor occupied
CAUSE
When the function "Board to center conveyor" started there already was a PCB board on the center
conveyor; sensor defective.
When the belt speed was set the center conveyor was occupied.
REMEDY
Remove the PCB board; fit new sensor.
245 Output conveyor occupied
CAUSE
When the function "Board to output conveyor" started there already was a PCB board on the output
conveyor; sensor of output conveyor defective.
When the belt speed was set output conveyor was occupied.
REMEDY
Remove the PCB board; fit new sensor.
246 BERO of left table side is not activated
CAUSE
Bero is not covered.
REMEDY
Check Bero.
247 Error in axis programming (left table side)
CAUSE
Bero of the left table side defective; axis could not be moved.
REMEDY
Check Bero; reboot.
SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 25
248 BERO of left table side responding constantly
CAUSE
Bero constantly covered.
REMEDY
Check Bero.
249 Width adjustment at limit switch maximum width
CAUSE
Width adjustment moved up to the limit switch; limit switch defective.
REMEDY
Move width adjustment in other direction; fit new limit switch.
250 Width adjustment at limit switch minimum width
CAUSE
Width adjustment moved up to the limit switch; limit switch defective.
REMEDY
Move width adjustment in other direction; fit new limit switch.
251 PCB on conveyor during width adjustment
CAUSE
PCB board on conveyor during width adjustment.
REMEDY
Remove the PCB board.
252 Hardware error: software relay for op.voltage defective
CAUSE
Relay K5 defective.
REMEDY
Replace relay K5.
253 Hardware error: no operating voltage
CAUSE
Cover open; start button pressed too briefly.
REMEDY
Close cover completely; press start button longer.
254 Hardware error: protective interlocking is defective
CAUSE
The protective switch is defective.
REMEDY
Replace protective switch.