19 Error Messages S IPLACE 80S/F/G User’s Manual 19.1 Error Mess ages Edition 12/96 from Software Vers ion SR.009.xx 19 - 26 255 Undefined error me ssage CAUSE ● Shoul d not occur. REMEDY ● Info rm SMD Servi ce. 256 Unde…

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 25
248 BERO of left table side responding constantly
CAUSE
●
Bero constantly covered.
REMEDY
●
Check Bero.
249 Width adjustment at limit switch maximum width
CAUSE
●
Width adjustment moved up to the limit switch; limit switch defective.
REMEDY
●
Move width adjustment in other direction; fit new limit switch.
250 Width adjustment at limit switch minimum width
CAUSE
●
Width adjustment moved up to the limit switch; limit switch defective.
REMEDY
●
Move width adjustment in other direction; fit new limit switch.
251 PCB on conveyor during width adjustment
CAUSE
●
PCB board on conveyor during width adjustment.
REMEDY
●
Remove the PCB board.
252 Hardware error: software relay for op.voltage defective
CAUSE
●
Relay K5 defective.
REMEDY
●
Replace relay K5.
253 Hardware error: no operating voltage
CAUSE
●
Cover open; start button pressed too briefly.
REMEDY
●
Close cover completely; press start button longer.
254 Hardware error: protective interlocking is defective
CAUSE
●
The protective switch is defective.
REMEDY
●
Replace protective switch.

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 26
255 Undefined error message
CAUSE
●
Should not occur.
REMEDY
●
Inform SMD Service.
256 Undefined error number from MVS (ED)
CAUSE
●
Should not occur.
REMEDY
●
Inform SMD Service.
257 Undefined error number from MVS (EF)
CAUSE
●
Should not occur.
REMEDY
●
Inform SMD Service.
258 Vacuum of the holding circuit is too low
CAUSE
●
Segments leaky; compressed air too low; vacuum circuit defective.
REMEDY
●
Check segments; adjust compressed air; replace vacuum circuit.
259 Axis command invalid at present
CAUSE
●
Axis board defective; local machine data incorrect; error should not occur.
REMEDY
●
Fit new axis board.
260 Illegal bit combination in handshake byte
CAUSE
●
Axis board defective; local machine data incorrect; error should not occur.
REMEDY
●
Fit new axis board.
261 Component too large for opt. multiple measurement
CAUSE
●
The number of measurements determined by the vision system is greater than the maximum permit-
ted number.
REMEDY
●
Check the package form data.

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 27
262 Undefined axis command
CAUSE
●
Axis board defective; local machine data incorrect; error should not occur.
REMEDY
●
Fit new axis board.
263 Undefined positioning type
CAUSE
●
Axis board defective; local machine data incorrect; error should not occur.
REMEDY
●
Fit new axis board.
264 Limit switch actuated
CAUSE
●
Limit switch defective; axis miscounting and moving up against limit switch.
REMEDY
●
Clean scale; call SMD Service.
265 Position outside travel range
CAUSE
●
Error in the local machine data.
REMEDY
●
Check positions.
266 Position contains an invalid character
CAUSE
●
Axis board defective; local machine data incorrect; error should not occur.
REMEDY
●
Fit new axis board.
267 Position contains an invalid prefix character
CAUSE
●
Axis board defective; local machine data incorrect; error should not occur.
REMEDY
●
Fit new axis board.
268 Undefined reference point type
CAUSE
●
Axis board defective; local machine data incorrect; error should not occur.
REMEDY
●
Fit new axis board.