00191025-01 - 第614页
SIPLACE 80S/F/G User’s Manual 19 Error Message s Edition 12/96 from S oftware Version SR.009.xx 19.1 Error Messages 19 - 27 262 Undefined axi s command CAUSE ● Axis boa rd defectiv e; local ma chine dat a incorre ct; err…

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 26
255 Undefined error message
CAUSE
●
Should not occur.
REMEDY
●
Inform SMD Service.
256 Undefined error number from MVS (ED)
CAUSE
●
Should not occur.
REMEDY
●
Inform SMD Service.
257 Undefined error number from MVS (EF)
CAUSE
●
Should not occur.
REMEDY
●
Inform SMD Service.
258 Vacuum of the holding circuit is too low
CAUSE
●
Segments leaky; compressed air too low; vacuum circuit defective.
REMEDY
●
Check segments; adjust compressed air; replace vacuum circuit.
259 Axis command invalid at present
CAUSE
●
Axis board defective; local machine data incorrect; error should not occur.
REMEDY
●
Fit new axis board.
260 Illegal bit combination in handshake byte
CAUSE
●
Axis board defective; local machine data incorrect; error should not occur.
REMEDY
●
Fit new axis board.
261 Component too large for opt. multiple measurement
CAUSE
●
The number of measurements determined by the vision system is greater than the maximum permit-
ted number.
REMEDY
●
Check the package form data.

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 27
262 Undefined axis command
CAUSE
●
Axis board defective; local machine data incorrect; error should not occur.
REMEDY
●
Fit new axis board.
263 Undefined positioning type
CAUSE
●
Axis board defective; local machine data incorrect; error should not occur.
REMEDY
●
Fit new axis board.
264 Limit switch actuated
CAUSE
●
Limit switch defective; axis miscounting and moving up against limit switch.
REMEDY
●
Clean scale; call SMD Service.
265 Position outside travel range
CAUSE
●
Error in the local machine data.
REMEDY
●
Check positions.
266 Position contains an invalid character
CAUSE
●
Axis board defective; local machine data incorrect; error should not occur.
REMEDY
●
Fit new axis board.
267 Position contains an invalid prefix character
CAUSE
●
Axis board defective; local machine data incorrect; error should not occur.
REMEDY
●
Fit new axis board.
268 Undefined reference point type
CAUSE
●
Axis board defective; local machine data incorrect; error should not occur.
REMEDY
●
Fit new axis board.

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 28
269 Acceleration/deceleration too great
CAUSE
●
Axis board defective; local machine data incorrect; error should not occur.
REMEDY
●
Fit new axis board.
270 PCB interrupted due to EMERGENCY STOP
CAUSE
●
The guard was opened or the EMERGENCY STOP button pressed while placement was in
progress.
REMEDY
●
Before opening the guard press the STOP switch and wait until the machine stops.
271 Check sum error of coplanarity
CAUSE
●
Error in the command to the coplanarity.
REMEDY
●
Repeat measurement; check supply voltage; jumper check.
272 Vision system not providing measure result
CAUSE
●
No component at the nozzle; component outside tolerance; not enough image information to provide
measurement result.
REMEDY
●
Optimize pick-up; check charge (component) .
273 Undefined error number from CRDL (0B)
CAUSE
●
Should not occur.
REMEDY
●
274 Fiducial type (fid/ink spot) not correct
CAUSE
●
Should not occur.
REMEDY
275 VS: Unknown request
CAUSE
●
Incorrect ICOS software version.
REMEDY
●
Check eproms and replace if necessary.