19 Error Messages S IPLACE 80S/F/G User’s Manual 19.1 Error Mess ages Edition 12/96 from Software Vers ion SR.009.xx 19 - 28 269 Acceleration/dec eleration too great CAUSE ● Axis boar d defectiv e; local mac hine data in…

100%1 / 736
SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 27
262 Undefined axis command
CAUSE
Axis board defective; local machine data incorrect; error should not occur.
REMEDY
Fit new axis board.
263 Undefined positioning type
CAUSE
Axis board defective; local machine data incorrect; error should not occur.
REMEDY
Fit new axis board.
264 Limit switch actuated
CAUSE
Limit switch defective; axis miscounting and moving up against limit switch.
REMEDY
Clean scale; call SMD Service.
265 Position outside travel range
CAUSE
Error in the local machine data.
REMEDY
Check positions.
266 Position contains an invalid character
CAUSE
Axis board defective; local machine data incorrect; error should not occur.
REMEDY
Fit new axis board.
267 Position contains an invalid prefix character
CAUSE
Axis board defective; local machine data incorrect; error should not occur.
REMEDY
Fit new axis board.
268 Undefined reference point type
CAUSE
Axis board defective; local machine data incorrect; error should not occur.
REMEDY
Fit new axis board.
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 28
269 Acceleration/deceleration too great
CAUSE
Axis board defective; local machine data incorrect; error should not occur.
REMEDY
Fit new axis board.
270 PCB interrupted due to EMERGENCY STOP
CAUSE
The guard was opened or the EMERGENCY STOP button pressed while placement was in
progress.
REMEDY
Before opening the guard press the STOP switch and wait until the machine stops.
271 Check sum error of coplanarity
CAUSE
Error in the command to the coplanarity.
REMEDY
Repeat measurement; check supply voltage; jumper check.
272 Vision system not providing measure result
CAUSE
No component at the nozzle; component outside tolerance; not enough image information to provide
measurement result.
REMEDY
Optimize pick-up; check charge (component) .
273 Undefined error number from CRDL (0B)
CAUSE
Should not occur.
REMEDY
274 Fiducial type (fid/ink spot) not correct
CAUSE
Should not occur.
REMEDY
275 VS: Unknown request
CAUSE
Incorrect ICOS software version.
REMEDY
Check eproms and replace if necessary.
SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 29
276 VS: Data not correct during request
CAUSE
Incorrect camera number in IDEAL.MA; obsolete ICOS software version.
REMEDY
Correct the machine data (IDEAL.MA); check eproms and replace if necessary.
277 VS: Check sum error during data transmission
CAUSE
Communications error
REMEDY
If the error reoccurs with further attempts, first reset MVS, then station computer.
278 VS: Reference No. unknown, model not found
CAUSE
The station refers to a package form or fiducial description which is not loaded in MVS/M10000.
REMEDY
Load fiducials/package form description from vision system; check camera codes (IDEAL.MA/
REAL.MA).
279 VS: Incorrect parameters during request
CAUSE
Incorrect camera number in IDEAL.MA; obsolete ICOS software version; FOV (field of view) data in
REAL.MA have too great a value.
REMEDY
Correct the machine data (IDEAL.MA and REAL.MA); check eproms and replace if necessary.
280 VS: Not enough memory for a window definition
CAUSE
Memory problems in the ICOS.
REMEDY
Reset ICOS.
281 VS: Not enough memory for a definition
CAUSE
ICOS cannot accept any further model descriptions.
REMEDY
Reset ICOS and reload.
282 VS: Not enough memory for image
CAUSE
Memory location problems in the ICOS.
REMEDY
Reset ICOS.