00191025-01 - 第615页
19 Error Messages S IPLACE 80S/F/G User’s Manual 19.1 Error Mess ages Edition 12/96 from Software Vers ion SR.009.xx 19 - 28 269 Acceleration/dec eleration too great CAUSE ● Axis boar d defectiv e; local mac hine data in…

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 27
262 Undefined axis command
CAUSE
●
Axis board defective; local machine data incorrect; error should not occur.
REMEDY
●
Fit new axis board.
263 Undefined positioning type
CAUSE
●
Axis board defective; local machine data incorrect; error should not occur.
REMEDY
●
Fit new axis board.
264 Limit switch actuated
CAUSE
●
Limit switch defective; axis miscounting and moving up against limit switch.
REMEDY
●
Clean scale; call SMD Service.
265 Position outside travel range
CAUSE
●
Error in the local machine data.
REMEDY
●
Check positions.
266 Position contains an invalid character
CAUSE
●
Axis board defective; local machine data incorrect; error should not occur.
REMEDY
●
Fit new axis board.
267 Position contains an invalid prefix character
CAUSE
●
Axis board defective; local machine data incorrect; error should not occur.
REMEDY
●
Fit new axis board.
268 Undefined reference point type
CAUSE
●
Axis board defective; local machine data incorrect; error should not occur.
REMEDY
●
Fit new axis board.

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 28
269 Acceleration/deceleration too great
CAUSE
●
Axis board defective; local machine data incorrect; error should not occur.
REMEDY
●
Fit new axis board.
270 PCB interrupted due to EMERGENCY STOP
CAUSE
●
The guard was opened or the EMERGENCY STOP button pressed while placement was in
progress.
REMEDY
●
Before opening the guard press the STOP switch and wait until the machine stops.
271 Check sum error of coplanarity
CAUSE
●
Error in the command to the coplanarity.
REMEDY
●
Repeat measurement; check supply voltage; jumper check.
272 Vision system not providing measure result
CAUSE
●
No component at the nozzle; component outside tolerance; not enough image information to provide
measurement result.
REMEDY
●
Optimize pick-up; check charge (component) .
273 Undefined error number from CRDL (0B)
CAUSE
●
Should not occur.
REMEDY
●
274 Fiducial type (fid/ink spot) not correct
CAUSE
●
Should not occur.
REMEDY
275 VS: Unknown request
CAUSE
●
Incorrect ICOS software version.
REMEDY
●
Check eproms and replace if necessary.

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 29
276 VS: Data not correct during request
CAUSE
●
Incorrect camera number in IDEAL.MA; obsolete ICOS software version.
REMEDY
●
Correct the machine data (IDEAL.MA); check eproms and replace if necessary.
277 VS: Check sum error during data transmission
CAUSE
●
Communications error
REMEDY
●
If the error reoccurs with further attempts, first reset MVS, then station computer.
278 VS: Reference No. unknown, model not found
CAUSE
●
The station refers to a package form or fiducial description which is not loaded in MVS/M10000.
REMEDY
●
Load fiducials/package form description from vision system; check camera codes (IDEAL.MA/
REAL.MA).
279 VS: Incorrect parameters during request
CAUSE
●
Incorrect camera number in IDEAL.MA; obsolete ICOS software version; FOV (field of view) data in
REAL.MA have too great a value.
REMEDY
●
Correct the machine data (IDEAL.MA and REAL.MA); check eproms and replace if necessary.
280 VS: Not enough memory for a window definition
CAUSE
●
Memory problems in the ICOS.
REMEDY
●
Reset ICOS.
281 VS: Not enough memory for a definition
CAUSE
●
ICOS cannot accept any further model descriptions.
REMEDY
●
Reset ICOS and reload.
282 VS: Not enough memory for image
CAUSE
●
Memory location problems in the ICOS.
REMEDY
●
Reset ICOS.