00191025-01 - 第616页

SIPLACE 80S/F/G User’s Manual 19 Error Message s Edition 12/96 from S oftware Version SR.009.xx 19.1 Error Messages 19 - 29 276 VS: Data not corr ect during request CAUSE ● Incorrec t camera n umber in IDEAL. MA; obsolet…

100%1 / 736
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 28
269 Acceleration/deceleration too great
CAUSE
Axis board defective; local machine data incorrect; error should not occur.
REMEDY
Fit new axis board.
270 PCB interrupted due to EMERGENCY STOP
CAUSE
The guard was opened or the EMERGENCY STOP button pressed while placement was in
progress.
REMEDY
Before opening the guard press the STOP switch and wait until the machine stops.
271 Check sum error of coplanarity
CAUSE
Error in the command to the coplanarity.
REMEDY
Repeat measurement; check supply voltage; jumper check.
272 Vision system not providing measure result
CAUSE
No component at the nozzle; component outside tolerance; not enough image information to provide
measurement result.
REMEDY
Optimize pick-up; check charge (component) .
273 Undefined error number from CRDL (0B)
CAUSE
Should not occur.
REMEDY
274 Fiducial type (fid/ink spot) not correct
CAUSE
Should not occur.
REMEDY
275 VS: Unknown request
CAUSE
Incorrect ICOS software version.
REMEDY
Check eproms and replace if necessary.
SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 29
276 VS: Data not correct during request
CAUSE
Incorrect camera number in IDEAL.MA; obsolete ICOS software version.
REMEDY
Correct the machine data (IDEAL.MA); check eproms and replace if necessary.
277 VS: Check sum error during data transmission
CAUSE
Communications error
REMEDY
If the error reoccurs with further attempts, first reset MVS, then station computer.
278 VS: Reference No. unknown, model not found
CAUSE
The station refers to a package form or fiducial description which is not loaded in MVS/M10000.
REMEDY
Load fiducials/package form description from vision system; check camera codes (IDEAL.MA/
REAL.MA).
279 VS: Incorrect parameters during request
CAUSE
Incorrect camera number in IDEAL.MA; obsolete ICOS software version; FOV (field of view) data in
REAL.MA have too great a value.
REMEDY
Correct the machine data (IDEAL.MA and REAL.MA); check eproms and replace if necessary.
280 VS: Not enough memory for a window definition
CAUSE
Memory problems in the ICOS.
REMEDY
Reset ICOS.
281 VS: Not enough memory for a definition
CAUSE
ICOS cannot accept any further model descriptions.
REMEDY
Reset ICOS and reload.
282 VS: Not enough memory for image
CAUSE
Memory location problems in the ICOS.
REMEDY
Reset ICOS.
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 30
283 VS: Unused free error number
CAUSE
Should not occur.
REMEDY
284 VS: A request is now being processed
CAUSE
A request is being processed in the vision system.
REMEDY
If this error still occurs after numerous attempts, reset ICOS.
285 VS: Request cannot be finished and is being aborted
CAUSE
The station refers to a package form or fiducial description which is not loaded in MVS/M10000.
REMEDY
Load fiducials/package form description from vision system; check camera codes (IDEAL.MA/
REAL.MA).
286 VS: Hardware error in vision system (FATAL ERROR)
CAUSE
Hardware error
REMEDY
If this error still occurs after numerous attempts, reset ICOS.
287 Coplanarity has received a hardware break
CAUSE
A hardware break was sent to the coplanarity module.
REMEDY
Hardware error: check coplanarity module; check M18; check supply voltage of the coplanarity mod-
ule.
288 Telegram to coplanarity has no STX
CAUSE
The first character sent to the coplanarity module is lost.
REMEDY
Check supply voltage; check jumper; repeat measurement.
289 Undefined error message
CAUSE
Should not occur.
REMEDY