19 Error Messages S IPLACE 80S/F/G User’s Manual 19.1 Error Mess ages Edition 12/96 from Software Vers ion SR.009.xx 19 - 30 283 VS: Unused fre e error number CAUSE ● Shoul d not occur. REMEDY ● 284 VS: A request is now …

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 29
276 VS: Data not correct during request
CAUSE
●
Incorrect camera number in IDEAL.MA; obsolete ICOS software version.
REMEDY
●
Correct the machine data (IDEAL.MA); check eproms and replace if necessary.
277 VS: Check sum error during data transmission
CAUSE
●
Communications error
REMEDY
●
If the error reoccurs with further attempts, first reset MVS, then station computer.
278 VS: Reference No. unknown, model not found
CAUSE
●
The station refers to a package form or fiducial description which is not loaded in MVS/M10000.
REMEDY
●
Load fiducials/package form description from vision system; check camera codes (IDEAL.MA/
REAL.MA).
279 VS: Incorrect parameters during request
CAUSE
●
Incorrect camera number in IDEAL.MA; obsolete ICOS software version; FOV (field of view) data in
REAL.MA have too great a value.
REMEDY
●
Correct the machine data (IDEAL.MA and REAL.MA); check eproms and replace if necessary.
280 VS: Not enough memory for a window definition
CAUSE
●
Memory problems in the ICOS.
REMEDY
●
Reset ICOS.
281 VS: Not enough memory for a definition
CAUSE
●
ICOS cannot accept any further model descriptions.
REMEDY
●
Reset ICOS and reload.
282 VS: Not enough memory for image
CAUSE
●
Memory location problems in the ICOS.
REMEDY
●
Reset ICOS.

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 30
283 VS: Unused free error number
CAUSE
●
Should not occur.
REMEDY
●
284 VS: A request is now being processed
CAUSE
●
A request is being processed in the vision system.
REMEDY
●
If this error still occurs after numerous attempts, reset ICOS.
285 VS: Request cannot be finished and is being aborted
CAUSE
●
The station refers to a package form or fiducial description which is not loaded in MVS/M10000.
REMEDY
●
Load fiducials/package form description from vision system; check camera codes (IDEAL.MA/
REAL.MA).
286 VS: Hardware error in vision system (FATAL ERROR)
CAUSE
●
Hardware error
REMEDY
●
If this error still occurs after numerous attempts, reset ICOS.
287 Coplanarity has received a hardware break
CAUSE
●
A hardware break was sent to the coplanarity module.
REMEDY
●
Hardware error: check coplanarity module; check M18; check supply voltage of the coplanarity mod-
ule.
288 Telegram to coplanarity has no STX
CAUSE
●
The first character sent to the coplanarity module is lost.
REMEDY
●
Check supply voltage; check jumper; repeat measurement.
289 Undefined error message
CAUSE
●
Should not occur.
REMEDY
●

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 31
290 Coplan.: Parameter number unknown
CAUSE
●
Should not occur.
REMEDY
●
291 Coplan.: Attempt to modify a Read Only Para
CAUSE
●
Should not occur
REMEDY
●
292 Communication to vision system defective (Error code -11)
CAUSE
●
System error
REMEDY
●
Reset system.
293 Communication to vision system defective (Error code -10)
CAUSE
●
System error
REMEDY
●
Reset system.
294 Communication to vision system defective (Error code -9)
CAUSE
●
System error
REMEDY
●
Reset system.
295 Communication to vision system defective (Error code -8)
CAUSE
●
System error
REMEDY
●
Reset system.
296 Communication to vision system defective (Error code -7)
CAUSE
●
System error
REMEDY
●
Reset system.