19 Error Messages S IPLACE 80S/F/G User’s Manual 19.1 Error Mess ages Edition 12/96 from Software Vers ion SR.009.xx 19 - 34 311 Undefined error n umber from vision syst em (FD) CAUSE ● System error REMEDY ● Reset s yste…

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 33
304 Communication to vision system defective (Error code 1)
CAUSE
●
System error
REMEDY
●
Reset system.
305 Undefined error number from CRDL (0C)
CAUSE
●
Should not occur.
REMEDY
●
306 Undefined error number from CRDL (0D)
CAUSE
●
Should not occur.
REMEDY
●
307 Undefined error number from CRDL (0E)
CAUSE
●
Should not occur.
REMEDY
●
308 Undefined error number from CRDL (0F)
CAUSE
●
Should not occur.
REMEDY
●
309 Undefined error number from CRDL (10)
CAUSE
●
Should not occur.
REMEDY
●
310 Undefined error number from trolley (E0)
CAUSE
●
Should not occur.
REMEDY
●

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 34
311 Undefined error number from vision system (FD)
CAUSE
●
System error
REMEDY
●
Reset system.
312 Coplan.: Component description has too many groups
CAUSE
●
Package form data erroneous.
REMEDY
●
Check package form data and respecify set-up.
313 Coplan.: Component number invalid
CAUSE
●
No component description exists for the component to be measured
REMEDY
●
Check set-up and respecify.
314 CRDL not initialized, test not possible
CAUSE
●
Incorrect command sent to tester.
REMEDY
●
If electrical testing is not possible, reset tester.
315 CRDL internal error (Error code 11H)
CAUSE
●
Hardware error at tester.
REMEDY
●
Reset station, if occurs repeatedly and electrical testing is not possible, replace tester.
316 CRDL internal error (Error code 12H)
CAUSE
●
Hardware error at tester.
REMEDY
●
Reset station, if occurs repeatedly and electrical testing is not possible, replace tester.
317 CRDL internal error (Error code 13H)
CAUSE
●
Hardware error at tester.
REMEDY
●
Reset station, if occurs repeatedly and electrical testing is not possible, replace tester.

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 35
318 CRDL internal error (Error code 14H)
CAUSE
●
Hardware error at tester.
REMEDY
●
Reset station, if occurs repeatedly and electrical testing is not possible, replace tester.
319 Format error of selected component in SMD data record (15H)
CAUSE
●
Erroneous CRDL component description
REMEDY
●
Check data record for CRDL test in the component description in the line computer and correct if
necessary.
320 Format error in measurement request (Error code 16H)
CAUSE
●
Incorrect command sent to tester.
REMEDY
●
If electrical testing is not possible, reset tester.
321 Undefined error number from CRDL (Error code 17H)
CAUSE
●
Hardware error at tester.
REMEDY
●
Reset station, if occurs repeatedly and electrical testing is not possible, replace tester.
322 CRDL internal error (Error code 18H)
CAUSE
●
Hardware error at tester.
REMEDY
●
Reset station, if occurs repeatedly and electrical testing is not possible, replace tester.
323 Still no compensation values in CRDL (Error code 19H)
CAUSE
●
Compensation not carried out.
REMEDY
●
Carry out compensation with single functions.
324 Undefined error number from CRDL (Error code 1AH)
CAUSE
●
Should not occur.
REMEDY
●