SIPLACE 80S/F/G User’s Manual 19 Error Message s Edition 12/96 from S oftware Version SR.009.xx 19.1 Error Messages 19 - 35 318 CRDL internal error (Error code 14H) CAUSE ● Hardware error at tester. REMEDY ● Reset s tati…

100%1 / 736
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 34
311 Undefined error number from vision system (FD)
CAUSE
System error
REMEDY
Reset system.
312 Coplan.: Component description has too many groups
CAUSE
Package form data erroneous.
REMEDY
Check package form data and respecify set-up.
313 Coplan.: Component number invalid
CAUSE
No component description exists for the component to be measured
REMEDY
Check set-up and respecify.
314 CRDL not initialized, test not possible
CAUSE
Incorrect command sent to tester.
REMEDY
If electrical testing is not possible, reset tester.
315 CRDL internal error (Error code 11H)
CAUSE
Hardware error at tester.
REMEDY
Reset station, if occurs repeatedly and electrical testing is not possible, replace tester.
316 CRDL internal error (Error code 12H)
CAUSE
Hardware error at tester.
REMEDY
Reset station, if occurs repeatedly and electrical testing is not possible, replace tester.
317 CRDL internal error (Error code 13H)
CAUSE
Hardware error at tester.
REMEDY
Reset station, if occurs repeatedly and electrical testing is not possible, replace tester.
SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 35
318 CRDL internal error (Error code 14H)
CAUSE
Hardware error at tester.
REMEDY
Reset station, if occurs repeatedly and electrical testing is not possible, replace tester.
319 Format error of selected component in SMD data record (15H)
CAUSE
Erroneous CRDL component description
REMEDY
Check data record for CRDL test in the component description in the line computer and correct if
necessary.
320 Format error in measurement request (Error code 16H)
CAUSE
Incorrect command sent to tester.
REMEDY
If electrical testing is not possible, reset tester.
321 Undefined error number from CRDL (Error code 17H)
CAUSE
Hardware error at tester.
REMEDY
Reset station, if occurs repeatedly and electrical testing is not possible, replace tester.
322 CRDL internal error (Error code 18H)
CAUSE
Hardware error at tester.
REMEDY
Reset station, if occurs repeatedly and electrical testing is not possible, replace tester.
323 Still no compensation values in CRDL (Error code 19H)
CAUSE
Compensation not carried out.
REMEDY
Carry out compensation with single functions.
324 Undefined error number from CRDL (Error code 1AH)
CAUSE
Should not occur.
REMEDY
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 36
325 Measure ranges exceeded (Error code 1BH)
CAUSE
Setpoint specified is incorrect; incorrect component at the nozzle; mismeasurement (jaws dirty)
REMEDY
Check data record for CRDL test in the component description in the line computer and correct if
necessary; check components; clean jaws.
326 Measured value outside tol. (Error code 1CH)
CAUSE
Error during course of measurement in the tester.
REMEDY
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
327 Measured value outside tol. (Error code 1DH)
CAUSE
Error during course of measurement in the tester.
REMEDY
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
328 Measured value outside tol. (Error code 1EH)
CAUSE
Error during course of measurement in the tester.
REMEDY
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
329 Measured value outside tol. (Error code 1FH)
CAUSE
Error during course of measurement in the tester.
REMEDY
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
330 Measured value outside tol. (Error code 20H)
CAUSE
Error during course of measurement in the tester.
REMEDY
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.