00191025-01 - 第623页

19 Error Messages S IPLACE 80S/F/G User’s Manual 19.1 Error Mess ages Edition 12/96 from Software Vers ion SR.009.xx 19 - 36 325 Measur e ranges excee ded (Er ror code 1B H) CAUSE ● Setpoint specified is inco rrect; inco…

100%1 / 736
SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 35
318 CRDL internal error (Error code 14H)
CAUSE
Hardware error at tester.
REMEDY
Reset station, if occurs repeatedly and electrical testing is not possible, replace tester.
319 Format error of selected component in SMD data record (15H)
CAUSE
Erroneous CRDL component description
REMEDY
Check data record for CRDL test in the component description in the line computer and correct if
necessary.
320 Format error in measurement request (Error code 16H)
CAUSE
Incorrect command sent to tester.
REMEDY
If electrical testing is not possible, reset tester.
321 Undefined error number from CRDL (Error code 17H)
CAUSE
Hardware error at tester.
REMEDY
Reset station, if occurs repeatedly and electrical testing is not possible, replace tester.
322 CRDL internal error (Error code 18H)
CAUSE
Hardware error at tester.
REMEDY
Reset station, if occurs repeatedly and electrical testing is not possible, replace tester.
323 Still no compensation values in CRDL (Error code 19H)
CAUSE
Compensation not carried out.
REMEDY
Carry out compensation with single functions.
324 Undefined error number from CRDL (Error code 1AH)
CAUSE
Should not occur.
REMEDY
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 36
325 Measure ranges exceeded (Error code 1BH)
CAUSE
Setpoint specified is incorrect; incorrect component at the nozzle; mismeasurement (jaws dirty)
REMEDY
Check data record for CRDL test in the component description in the line computer and correct if
necessary; check components; clean jaws.
326 Measured value outside tol. (Error code 1CH)
CAUSE
Error during course of measurement in the tester.
REMEDY
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
327 Measured value outside tol. (Error code 1DH)
CAUSE
Error during course of measurement in the tester.
REMEDY
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
328 Measured value outside tol. (Error code 1EH)
CAUSE
Error during course of measurement in the tester.
REMEDY
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
329 Measured value outside tol. (Error code 1FH)
CAUSE
Error during course of measurement in the tester.
REMEDY
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
330 Measured value outside tol. (Error code 20H)
CAUSE
Error during course of measurement in the tester.
REMEDY
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 37
331 Measured value outside tol. (Error code 21H)
CAUSE
Error during course of measurement in the tester.
REMEDY
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
332 Measured value outside tol. (Error code 22H)
CAUSE
Error during course of measurement in the tester.
REMEDY
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
333 Phase error during CRDL measurement (Error code 23H)
CAUSE
Incorrect component part at the nozzle; angle of the phase shift outside tolerance.
REMEDY
Check component supply, set-up.
334 Measured value outside tol. (Error code 24H)
CAUSE
Error during course of measurement in the tester.
REMEDY
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
335 Measured value outside tol. (Error code 25H)
CAUSE
Error during course of measurement in the tester.
REMEDY
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
336 Measured value outside tol. (Error code 26H)
CAUSE
Error during course of measurement in the tester.
REMEDY
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.